![Tormax Automatic iMotion 2202 Instructions For Use Manual Download Page 16](http://html1.mh-extra.com/html/tormax-automatic/imotion-2202/imotion-2202_instructions-for-use-manual_1130471016.webp)
16
Instructions for use T-1321 e
7 Maintenance
The system was tested and approved by an expert before initial commissioning. The manufacturer
recommends that you conclude a service contract in order to maintain the value of your system for as
long as possible as well as to ensure the system operates reliably and safely for a long time.
Only genuine TORMAX spare part should be used. The manufacturer accepts no liability if you fail
to observe this requirement. Original spare parts and original accessories guarantee the safety of
use in accordance with norm EN 16005.
Warning
Possible risk of injury!
Entrapment of limbs can lead to serious injury.
• The drive must be disconnected from all power sources, including batteries during clean-
ing, maintenance and replacement of parts.
7.1 Cleaning
• Clean casing parts, the user interface and door leaves with a damp cloth and a commercial cleaner.
7.2 Functional Checks
• Check the door system’s function and safety devices at least every 3 months.
This will ensure that faults or hazardous changes in the system are detected at an early stage. See
chapter 8.2 “Check-list for Functional Checks” for items to be checked.
• You should arrange for any defects detected during the routine checks to be rectified immediately by
a TORMAX dealer (see the last page of this Manual for the address).
Warning
Potential switching malfunction in the automatic sliding door.
Potential hazards – injury caused by impact or crushing.
• Secure the area around the door while checking the door's functions.
7.3 Maintenance and Testing
Maintenance and testing should only be carried out by a trained specialist following the manufacturer’s
instructions.
Maintenance Interval
The maintenance interval depends on the frequency of use but the system must be maintained
at least once per year.
Scope of the Maintenance Work
The content of the maintenance work is specified by the manufacturer in an inspection list.
System Test Book
The test findings are recorded after the test in the system test book. The operator must keep it in a safe
place.