4. Identify the Accessory 1 input connector and the Accessory 2
input connector on the ECM board (both white). To correctly
reinstall them later in this procedure, put a mark on the top
connector (Accessory 1) with a marker.
NOTICE!
If the accessory input connectors are put back
incorrectly, it could damage any (optional) accessory
probes.
5. Disconnect each connector from the ECM board.
6. Use your fingers to loosen and remove the four brass
standoffs that secure the ECM board to the electrical panel.
Figure 2-3: Four standoffs securing the ECM board to the
electrical cabinet.
7. Set aside the ECM v1.4 board.
8. Remove the remaining four brass standoffs from the
electrical cabinet. Then, discard all eight brass standoffs that
you removed in this procedure.
2.1.2 Install the ECM v1.5 Board
1. For the ECM v1.5 board to correctly fit in the electrical
cabinet, you must first remove two tabs from the top wire
trough: bend the tabs back-and-forth until you can remove
them from the wire trough, as shown in the following image.
Figure 2-4: Two tabs removed from the top wire trough.
2. Find the eight nylon standoffs provided.
NOTICE!
To prevent damage to the ECM board from
over-tightening, use your fingers to tighten the
standoffs.
3. In place of the four brass standoffs that you removed in
"Remove the ECM v1.4 Board" (on the previous page), install
four nylon standoffs into the electrical cabinet.
4. Find the ECM v1.5, and remove it from the electrostatic safe
bag. Then, set the bag aside.
Note:
To receive a refund/core charge payment, you
must return the ECM v1.4 board back to us in the
electrostatic safe bag provided.
5. Mount the ECM v1.5 board into the electrical cabinet with the
four remaining nylon standoffs. Verify that the logo on the
ECM board is upright, as shown in the following image.
Figure 2-5: ECM v1.5 board installed in the electrical
cabinet.
6. Identify the jumpers on the ECM v1.5 board, as shown in the
following image.
Figure 2-6: Jumper on the ECM v1.5 board.
Page 4
©Tormach® 2020
Specifications subject to change without notice.
tormach.com
TD10571: Installation Guide: ECMv1.5 Update Kit (0420A)