Tork EasyCube User Manual Download Page 19

FCC:

by the party responsible for compliance could void the user’s 

authority to operate the equipment. 
This device complies with Part 15 of the FCC Rules. Operation is 

subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this de-

vice must accept any interference received, including interference 

that may cause undesired operation. 
NOTE: This equipment has been tested and found to comply with 

the  limits  for  a  Class  B  digital  device,  pursuant  to  Part  15  of  the 

FCC  Rules.  These  limits  are  designed  to  provide  reasonable  pro-

tection  against  armful  interference  in  a  residential  installation.  This 

equipment generates, uses and can radiate radio frequency energy 

and,  if  not  installed  and  used  in  accordance  with  the  instructions, 

may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to ra-

dio or television reception, the user is encouraged to contact SCA 
for support.
FCC ID: 2ABK3-682870 (article number 682870)

FCC ID: 2ABK3-682850 (article number 682850)

FCC ID: 2ABK3-682920 (article number 682920), contains FCC ID: QIPEHS6

FCC ID: 2ABK3-682830 (article numbers 682830, 682840)

FCC ID: 2ABK3-466200 (article number 466200)

FCC ID: 2ABK3-682930 (article number 682930)

18

Summary of Contents for EasyCube

Page 1: ...Tork EasyCubeTM User Manual www torkglobal com...

Page 2: ...ration units that count people passing into a washroom area or a cubicle Combining these information sources gives many opportunities to improve both The information is automatically transferred via t...

Page 3: ...Figure 1 Each dispenser is wirelessly connected to an information system that can be utilized by both a Facility Manager as well as cleaning staff in order to 2...

Page 4: ...mer together with Essity will determine which rooms will be included and the required number of gateways see chapter 3 6 for further explanation to support these locations The number of gateways requi...

Page 5: ...terface Sensors Internet Connection in status occurs the gateway forwards the information to the Tork EasyCube It is in the application server in the cloud where all data is processed and aggregated t...

Page 6: ...requency band The sensors are capable of two directional com munications Each unit transmits usage data as well as operational conditions such as battery level It can also be instructed to fall asleep...

Page 7: ...r 682930 The Level Sensor is used for the following dispensers Article number Tork Elevation Xpress Hand Towel Dispenser 552020 552028 Tork Image Design Xpress Hand Towel Dispenser 463002 Tork Xpress...

Page 8: ...the sensor is placed looks different for different dispensers the illustration shows one example The battery change procedure is the same for all the dispensers To change battery 1 2 3 Take out the le...

Page 9: ...4 6 7 5 Remove the battery Replace with a new Essity approved battery Put the sensor into the bracket in the dispenser again Recycle used batteries according to regulations Close the cover again 8...

Page 10: ...Tork EasyCube by colors Each sensor is operated by an embedded battery Wipe off with a dry cloth each 6 months or when needed to remove dust Article number 682870 Figure 5 Sensor Green indicates that...

Page 11: ...Dispenser Recessed Tork Image Design Matic Hand Towel Roll Dispenser in Wall Recessed 461002 461022 461023 Tork Elevation PeakServe Hand Towel Dispenser 552520 552528 Tork Elevation Twin Mini Jumbo B...

Page 12: ...tional sensor Instead there is an additional radio component in the cassette which forwards information to the gateway via 2 4 GHz radio The system runs on the same battery as the dispenser no additio...

Page 13: ...line for when washrooms need to be cleaned end pieces and rotate the center unit 90 to change direction Place one sender and one receiver at the door frame to the entry of the room The sensor has a ra...

Page 14: ...eway is installed away from water and as high up as possible for best performance Figure 8 Gateway The gateway has a built in 2G 3G modem used to connect to Internet No access to local physical networ...

Page 15: ...14...

Page 16: ...or Communication Unit Sensors Light Battery 3V 500mAh CR3032 Dimensions 62 x 50 x 6mm 2 4 x 2 0 x 0 2 inches Visitor Registration Unit Sensors Infrared IR Battery 3 6V 2 1Ah 2 3A Dimensions 158 x 23 x...

Page 17: ...mperatures disassemble it damage it mechanically or put the Only use the SIM card provided by Essity If any of the contents of the Tork EasyCubeTM appear to be damaged or broken contact Essity Custome...

Page 18: ...ation can be accessed from modern web browsers Devices shown are not actual size Important Save this user manual for future reference If any changes to the installation are necessary please contact al...

Page 19: ...ion against armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may...

Page 20: ...ils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l utilisateur de l appareil doit accepter tout brouillage radi...

Page 21: ...improving the environmental performance of batteries and accumulators CE marking is a mandatory conformity marking for certain products sold within the European Economic Area EEA The CE marking is als...

Page 22: ...21...

Page 23: ...22...

Page 24: ...www torkglobal com Distributed by Essity Professional Hygiene North America LLC 2929 Arch Street Suite 2600 Philadelphia Pennsylvania 19104 www torkusa com Sensors Gateway and Visitor Registration un...

Reviews: