R
EMOTE
T
ASK
™
A
LPHA
P
ARTS AND
I
NSTALLATION
M
ANUAL
P
OST
I
NSTALLATION
77
V
ERSION
1.1
6.2 Post Installation Testing
The purpose of this section is to validate the system after installation. This document should be
used along with the RemoteTask Operation and Maintenance Manual. The Operation and
Maintenance Manual provides more details about the operation, controls, and feedback
provided by system.
Do not operate the machine unless you have read and understand the
instructions and warnings in the Operation and Maintenance manual.
Most
accidents that involve product operation are caused by failure to observe basic
safety rules or precautions. An accident can often be avoided by recognizing
potentially hazardous situations before an accident occurs. The operator should
have the necessary training, skills, and tools in order to perform operation and
safety functions properly.
The operator is responsible for safely operating the remote machine.
Ensure the remote operation area is clearly marked and personnel do not enter
the area during remote operation. Verify site personnel are aware the system
will be operating remotely. Maintain line-of-sight with the machine at all times
during remote operation.
Do not approach the machine if the Active Indicator (amber beacon) is
flashing.
Verify with the operator that it is safe to approach the machine.
6.2.1 Test In-Cab Machine Controls
A. Turn on the machine using the CAT key inside the cab.
B. Verify that manual operation of the machine has not been affected by the installation of
RemoteTask. Check that the driving controls and implement controls operate normally.
C. Ensure that no new diagnostic codes have been set.
D. Remove attached implements and proceed to test remote operation of the machine.
Summary of Contents for REMOTETASK ALPHA
Page 1: ......
Page 2: ...REMOTETASK ALPHA Parts and Installation Manual V1 1 ...