Checks and repairs on electrical components
34
Replace the defective remote control, see page 35.
Connect the multimeter to the wire of the (OFF) connection and the wire of
the (COM) connection.
Press the OFF button (A) on the remote control.
Measure the electrical resistance.
The resistance has to be significantly less than 10 Ω.
If the resistance is higher, the remote control is defective.
Replace the defective remote control, see page 35.