Do not open the feed water valve (V-1) quickly, or
water-hammer may occur and the module could be
damaged.
(5) Confirm that the air is out of the module, and then close the air exhaust valve
(V-4).
(6) Set appropriate volume of filtrate water flow.
Do not exceed 600 kPa (87.0 PSI) to avoid
damage to the module.
Operating conditions including the filtration flux
and the physical cleaning should be properly set
up, observing the rise of trans-membrane pressure
(Details are described in the next session.).
Please contact us if you need technical support.
(7) When stopping operation, gradually close the feed water valve (V-1).