Please see page 16 of your TopTENS™ Instruction Manual for troubleshooting tips.

PROBLEMS WITH YOUR DEVICE?

QUICK REFERENCE GUIDE 

PAGE 2

|

2

CONNECT ELECTRODES 

TO LEAD WIRES

Firmly insert

the end of 

the lead wire 

pin into the 

electrode 

connectors.

Make sure the connection is complete and 

no bare metal of the pins is exposed.

3

CONNECT LEAD WIRES 

TO TOP OF DEVICE

This unit operates 

with one or two 

sets of electrodes.  

When using one 

set, plug lead wire 

into Channel 1 

on top of the unit. 

Use Channel 2 to 

operate a second 

set of electrodes.

4

PLACE ELECTRODES

ON SKIN

6

SELECT PROGRAM

Remove electrodes 

from protective 

backing. Keep 

backing to properly 

store electrodes after 

use.

Before applying 

electrodes, make 

sure the skin at the 

application site is 

clean and dry. 

Pressing the 

Mode 

button will activate the default 

therapy mode setting, and will flash on the display. 

Press the 

On /

+

 

to increase the therapy mode or

 

Off /

 

to decrease.

7

SELECT DESIRED

TREATMENT TIME

Press the 

Mode

 button 

to select one of 12 preset 

treatment times ranging 

from 5-60 minutes or 

continuous. Press the 

On /

+

 

to increase the 

treatment time or

 Off /

to decrease.

8

SELECT THERAPY

INTENSITY LEVEL

Press the 

CH

 button to select the appropriate channel 

and intensity level for each. The CH1 / CH2 will flash on 

display.  Press the 

On /+ 

to increase the intensity level 

or

 Off /– 

to decrease to a comfortable level.

As a safety precaution, changing the therapy mode 

setting during a therapy session cause the intensity 

level to reset to O.

5

TOP VIEW

The TopTENS™ unit will turn off automatically when 

therapy time has elapsed. In continuous mode (

C

), 

the device must be turned off manually by pressing 

the 

Off/-

 button.

If you alter the program mode during your therapy, 

the treatment time will not restart unless you reset 

the therapy time.
As a safety feature, the intensity level will change to 

O when the Mode button is pressed during a session.

Low battery indicator           

signals when battery is

low.  Replace battery when stimulation feels weaker.

SPECIAL FEATURES

Steps 1 – 4 should be performed with the device turned OFF.

Once the unit has been turned ON, do not remove electrodes 

without first turning OFF the device. 

IMPORTANT!

Check that electrodes are securely placed on 

the skin before activating device.  Press the 

On /

+

 

button located on the far right of the control panel to 

turn the device ON.

See 

Electrode Placement Guide

 for more information.

1

INSERT BATTERY

Press arrow and slide battery compartment 

cover open. Insert the 3 AAA batteries, 

matching the + and – ends to those in unit. 

Do not remove or adjust electrodes until turning  the 

device off by pressing the 

Off /

 button for 3 seconds.

Changing the program setting during a therapy

session will not affect the selected treatment time.

Changing the treatment time setting during a therapy 

session will not affect the selected program.