To customize your 7 day program schedule, follow these steps:

Select 

HEAT

 or 

COOL

 using the system key. You have to program heat and cool each separately.

Press 

MENU

Press 

SET SCHED

Note:

 Monday is displayed and the 

WAKE

 icon is shown. You are now programming the 

WAKE

 

time period for the Monday setting. 

Time is flashing. Use the            or            key to make your time selection for the Monday 

WAKE

 

time period. 

Note:

 If you want the fan to run continuously during this time period, select 

ON

 with 

the 

FAN

 key.

Press 

NEXT STEP

The setpoint temperature is flashing. Use the          or         key to make your setpoint selection for 

the Monday 

WAKE

 period.

Press 

NEXT STEP

Repeat steps 4 thru 7 for Monday 

LEAVE

 time period, for Monday 

RETURN

 time period, and for 

Monday 

SLEEP

 time period.

PROGRAMMING THE THERMOSTAT

18

1.

2.

3.

4.

5.

6.

7.

8.

Monday

Repeat steps 4 thru 7 for the remaining days of the week.

Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday

A Note About Auto Changeover:

 

Auto changeover will switch between heating 
and cooling as needed. It is very important to 
make sure the cooling setpoint temperature is at 

least 3º above the heating setpoint temperature 

and that the heating setpoint temperature is at 

least 3º below the cooling setpoint temperature.

A Note About Programmable Fan:

The programmable fan feature will 
run the fan continuously during any 
time period it is programmed to be 
on. This is the best way to keep the 
air circulated and to eliminate hot 
and cold spots in your building.

Set 7 Day Program Schedule

Additional step if R251W indoor remote sensor is connected.

The 

T955W

 master thermostat will either average all sensors (system average) or only use 

one sensor for the system ambient temperature (priority).  The default setting is 

SYSTEM 

AVERAGE

, which means all sensors are averaged to create the system average ambient 

temperature reading.  The 

NEXT ZONE

 key can be pressed to change the priority.  

The system information area of the display shows the priority.

For Example:

 There is an 

R251W

 connected and it is named 

REMOTE 1

.  If the 

NEXT 

ZONE

 key is pressed until 

REMOTE 1

 is shown, then the 

REMOTE 1

 ambient temperature 

reading will be used exclusively for that time period.  All other sensors will be ignored. 

Summary of Contents for truecomfort iii

Page 1: ...with Battery Backup If using remote sensors the thermostat must be hardwired Power Type 1 Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Multi...

Page 2: ...hermostat becomes inoperable The batteries are located on the back of the thermostat Clean Display Pressing CLEAN DISPLAY will allow 30 seconds to clean the display The keys will be inoperable during...

Page 3: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Page 4: ...NOT weatherproof Base Module Basement Installation 4 PRO1 Tip Wireless Range Range between the T955W and the base module is up to 100 feet with no obstructions and up to 50 feet in standard residenti...

Page 5: ...rproof Base Module Attic Installation 5 PRO1 Tip When performing an attic installation instead of placing the base module in the attic locate the closet nearest to the air conditioning unit Then mount...

Page 6: ...ose of it properly Your local waste management authority can give you instructions on recycling and proper disposal For vertical mount put one screw top and one screw bottom For horizontal mount put o...

Page 7: ...ule s subbase the same way you would wire a hardwired thermostat subbase For vertical mount put one screw top and one screw bottom For horizontal mount put one screw left and one screw right Horizonta...

Page 8: ...factory to operate a conventional heating and cooling system This thermostat will also operate a heat pump system See the heat pump configuration step on page 12 of this manual to configure the thermo...

Page 9: ...is reestablished The Blue LED on the base module will also turn off to show communication has been lost Note The Blue LED on the base module will be on when power is present The Blue LED will flash 3...

Page 10: ...on The heating swing setting is adjustable from 0 2 F to 2 F For Example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approxi...

Page 11: ...r nonprogrammable Program Options Select F for Fahrenheit temperature read out or select C for Celsius read out F for Fahrenheit C for Celsius F F or C The second stage will turn on at 2x the swing se...

Page 12: ...enable the balance point tech setup option The cooling fan delay setting will delay the fan from coming on in cool mode and keep running after the compressor shuts off for a short time to save energy...

Page 13: ...ep Then hold down the light button on the R251W until it beeps while in ZONE technician setup step on R251W To connect a second R251W change the T955W to read 2 and change the R251W to zone 2 The zone...

Page 14: ...the thermostat or base module snaps in place On the back of the thermostat insert 2 AA Alkaline batteries included Battery installation is optional if there are no remotes connected to the Master Ther...

Page 15: ...low to set the day of the week and current time Press MENU Press SET TIME Day of the week will be flashing Use the or key to select the current day of the week Press NEXT STEP The current hour is flas...

Page 16: ...customized program schedule if using 5 1 1 Wake Leave Return Sleep Wake Leave Return Sleep Wake Leave Return Sleep Weekday Customize Your Program Saturday Sunday Day of the Week Setpoint Temperature...

Page 17: ...period Repeat steps 4 through 7 for Saturday WAKE time period for Saturday LEAVE time period for Saturday RETURN time period and for Saturday SLEEP time period 1 2 3 4 5 6 7 8 9 Sunday Repeat steps 4...

Page 18: ...as needed It is very important to make sure the cooling setpoint temperature is at least 3 above the heating setpoint temperature and that the heating setpoint temperature is at least 3 below the cool...

Page 19: ...e Battery power from 2 AA Alkaline batteries 32 F to 105 F 0 to 41 C 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D 916 MHz 19 SPECIFICATIONS CONTACT INFORMATION Specifications Pro1 IAQ Inc 1111 S Gl...