background image

3

213906-00 Rev. 3A 6/14

Application

The TechPure media air cleaner cabinet is designed 

to capture a significant amount of airborne particles. 

The cabinets are sold with MERV 11 or MERV 15 

filter media. TechPure media filter cabinets can be 

installed in all forced warm air furnaces and cooling 

systems up to 5 tons (2000 CFM).

TechPure MAC Tip

Choose a mounting location that 

is upstream of the furnace and/

or evaporator coil. This will keep 

the furnace and/or evaporator coil 

clean.

TechPure Install Tip

When installing the TechPure 

media air cleaner with a humidifier, 

choose a mounting location that 

will not allow the water mist to 

come in contact with the filter 

media.

Mounting Positions

The TechPure media air cleaner cabinet can be 

mounted in any position.

Installation

1. Plan the installation:

 

The TechPure media air cleaner cabinet is designed 

to support the weight of a residential furnace and 

residential evaporator coil. This media air cleaner 

can be mounted in any position in the return air duct. 

Typically, the  media air cleaner is mounted next to 

the furnace blower compartment.
The media air cleaner cabinet is designed to be 

installed in the return air duct. Do not mount the 

media air cleaner cabinet in the supply duct.
Install the media air cleaner cabinet in a manner 

that spreads airflow evenly across the filter media. 

Gradual transitions are required if the duct is a 

different size than the media air cleaner cabinet. 

To prevent turbulence, the maximum amount of 

expansion on each side of the transition is 20 

degrees.
Turning vanes are required if the duct turns sharply 

just before attaching to the media air cleaner cabinet. 

For example, turning vanes would be required if 

there is an abrupt 90 degree elbow in the duct 

directly next to the media air filter cabinet.

Install the media air cleaner cabinet in an area that 

allows for at least 27" of clearance in front of the 

cabinet door for easy replacement of the filter media.

INSTALLATION

Secure angled bracket 

front to back with 8x1/2 

self-tapping screws.

Secure flat bracket to 
bottom or back with 8x1/2 
self-tapping screws.

Summary of Contents for Technology series

Page 1: ...if you fail to follow these instructions Need Help For assistance with this product please visit http www toptechparts com or call customer care at 1 866 239 4440 during normal business hours Table of Contents Page Features and Specifications 2 Installation 3 Installation continued 4 Pressure Drop Data 5 Final Check and Contact Info 6 High performance media air cleaner Air cleaner cabinet is fully...

Page 2: ...75 D x 14 25 W x 6 H Repl Media TT FM 1425 TT FM15 1425 TT MAC 1729 29 D x 17 25 W x 6 H Repl Media TT FM 1625 TT FM15 1625 TT MAC 2129 29 D x 21 25 W x 6 H Repl Media TT FM 2025 TT FM15 2025 TT MAC 2429 29 D x 24 25 W x 6 H Repl Media TT FM 2424 TT FM15 2424 TT MAC 1722 22 125 D x 17 W x 6 H Repl Media TT FM 1620 TT FM15 1620 TT MAC 2122 22 125 D x 21 W x 6 H Repl Media TT FM 2020 TT FM15 2020 TT...

Page 3: ...aner can be mounted in any position in the return air duct Typically the media air cleaner is mounted next to the furnace blower compartment The media air cleaner cabinet is designed to be installed in the return air duct Do not mount the media air cleaner cabinet in the supply duct Install the media air cleaner cabinet in a manner that spreads airflow evenly across the filter media Gradual transi...

Page 4: ...ically point toward the blower compartment Installation continued 2 Fasten the media cabinet to the furnace Carefully create or use opening in the furnace or air handler to match the filter media cabinet opening Place enclosed gasket material on the side of the air cleaner that joins up with furnace or air handler You can attach the media cleaner cabinet directly to the furnace or air handler or f...

Page 5: ... mm Fractional Efficiency 0 3 0 4 15 7 15 1 21 2 26 3 34 2 38 5 15 1 0 4 0 55 19 9 19 5 25 9 36 3 42 9 51 2 19 5 0 55 0 7 28 0 30 6 39 8 52 3 57 6 65 8 28 6 0 7 1 0 42 0 45 3 52 6 65 9 71 2 79 3 43 0 1 0 1 3 53 4 57 8 63 7 74 8 81 4 86 6 53 4 1 3 1 6 61 5 65 9 72 0 81 5 85 9 91 3 61 5 1 6 2 2 69 1 74 8 80 3 86 9 90 9 95 0 69 1 2 2 3 0 77 0 82 9 88 2 93 2 95 0 97 2 77 0 3 0 4 0 81 7 88 0 92 2 95 7 ...

Page 6: ... least once a year in all circumstances Final Checks Check installation 1 TechPure air cleaner cabinet is installed securely on the return side of the system 2 The arrow on the filter media points in the direction of the air flow 3 If used turning vanes and transitions are installed properly 4 All joints in ductwork and between TechPure air cleaner and furnace air handler are properly sealed to pr...