TECHNICIAN SETUP

Fahrenheit/Celsius Display

12 or 24 Hour Time

Terminal Designations

Auxiliary heat relay - Stage 2
Compressor relay - Stage 1
Fan relay
Heat pump changeover valve 

energized in cooling
Transformer power

Common wire from 

system transformer
Heat pump changeover valve 

energized in heating
Emergency heat relay

W2

Y

G
O

R

C

B

E

Select 

F

 or 

C with the jumper pin on the 

back of the thermostat.  

F

 is for 

Fahrenheit and 

C is for Celsius.

12 or 24 hour (military time) can be 
selected with the jumper pin.

Important:

The 

RESET button must be 

pressed after changing any 
switch or jumper pin 
setting. Batteries must be 
installed for this operation.

12 or 24 hour 

jumper pin

Select 

F

 or 

C 

with the jumper pin

Reset button

Note:

In many systems with no emergency heat relay 

a jumper can be installed between E and W2.

Summary of Contents for T721 True Comfort III

Page 1: ...Mounting and Battery Installation Set Time Specifications and Contact U S Registered Trademark Patents pending Copyright 2006 Pro1 IAQ Inc All rights reserved Table of Contents Thermostat Applications...

Page 2: ...ld air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where ther...

Page 3: ...t Buttons 6 User Buttons 7 Displays the user selectable setpoint temperature System operation indicators The COOL HEAT or FAN icon will display when the COOL HEAT or FAN is on NOTE The compressor dela...

Page 4: ...roducts are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and proper dispos...

Page 5: ...al connections on the thermostat that is being replaced In some cases the wiring connections will not be color coded For example the green wire may not be connected to the G terminal Loosen the termin...

Page 6: ...gency heat relay W2 Y G O R C B E Select F or C with the jumper pin on the back of the thermostat F is for Fahrenheit and C is for Celsius 12 or 24 hour military time can be selected with the jumper p...

Page 7: ...wing setting often called cycle rate differential or anticipation is adjustable A smaller swing setting will cause more frequent cycles and a larger swing setting will cause fewer cycles When on this...

Page 8: ...UNT THERMOSTAT BATTERY INSTALLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place C O B E...

Page 9: ...ng Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m...

Page 10: ...erminal 1 5 amp maximum all terminals combined 1 F Heating is adjustable from 0 4 F to 2 0 F Cooling is adjustable from 0 4 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Batte...