CHAPTER 5
–
CONNECTING FIELD DEVICES TO THE I/O BOARD
54
MultiLoad II/ RCU II Explosion Proof Lite (EXL) Installation Guide - Part # 6070
RCU II DC Output Wiring
I/O DIGITAL/
ANALOG
I/O 2 METER
METER 0
METER 1
PORT 10.OUT/
PORT 10.IN/
PORT 0.10
PORT 10.OUT/
PORT 10.IN/
PORT 1.10
+
-
+
-
IN
1
✓
OUT 2
✓
IN
3
✓
OUT 4
✓
IN
5
✓
OUT 6
✓
IO_DA TB3
PORT 10
PORT 11
PORT 12
IN
1
✓
OUT 2
✓
IN
3
OUT 4
IO_2M TB9
PORT
0.10
IN
1
OUT 2
IN
3
✓
OUT 4
✓
IO_2M TB9
PORT
1.10
PORT 0.10.IN
PORT 1.10.OUT
PORT 1.10.IN
PORT 0.10.OUT
PORT 10/
PORT 10/
+
-
N.O.
N.C.
C
N
L
+
-
5
– 30 Vdc
+
-
L
N
Note: