![Toptec SE-GM29 Installation Manual Download Page 9](http://html1.mh-extra.com/html/toptec/se-gm29/se-gm29_installation-manual_1129893009.webp)
Installation Manual
Page 9 of 15
11.
Follow the instruction showed in the screen
.
Configure Modem
Using a terminal Package (e.g. ProComm, HyperTerminal)
1. Set the baud rate to 9600.
2. Send the command
AT+IPR=115200<CR> (or desired baud rate).
Do not send any more data at 9600 - this will reset the module as well.
3. Change Terminal Package baud rate to 115200.
4. To store user profile in non-volatile memory, send
AT&W=0<CR>
5. Setup GPRS data parameters (APN, etc.) using AT commands
AT+CGDCONT = 1, "IP", “operator’s internet APN", "", 0, 0.
AT+CGATT=1.