C260
GENERAL REMARKS AND SAFETY -2
INSTALLATION AND USE INSTRUCTIONS
7
TECHNICAL DATA
C260
MODEL
C260/230V
Power supply voltage
230V ~ 50Hz
Absorbed current
0,4 A
Absorbed power with load
80 W
Thrust force
600 N
Tractive force
600 N
Idle translation speed
13 mm/s
Duration of the idle stroke (2)
46 s
Protection against electric shock
Class II
Actuator length
1500 ÷ 4000 mm
Protection degree of electric devices
IP30
Type of service S2 (1)
4 min
Parallel electric connection of more actuators on different windows
Yes
Operating temperature
-5°C ÷ +50°C
Limit switch: Electronic for opening - by amperometric absorption for closing.
Actuator weight with brackets
4,9Kg - 8 Kg
Operation stroke(2)
600mm
USE OF THE ACTUATOR
•
The actuator can be used exclusively by an user acting in compliance with the instructions contained in this manual and/or in the
manual of the actuator control device (e.g.: wind and rain control unit).
•
Before using the actuator, it is compulsory for the user to read and understand in all its parts this manual, as well as the eventual
manual of the installed control device type.
•
Before operating the actuator, the user must compulsorily verify that near and/or under the window there are not any person, animal
and thing whose safety may be accidentally jeopardized.
•
During the operation of the actuator control device, the user has to compulsory occupy a safe control position assuring visual control
on the window movement.
•
It is compulsory to verify constantly in time the functional effi ciency and the rated performance of the actuator, of the window frame
where it is installed and of the electric plant, performing when necessary interventions of routine or supplementary maintenance
assuring operation conditions complying with safety regulations.
•
l above mentioned interventions can be performed only by competent and qualifi ed technical personnel meeting the professional
and technical requirements foreseen by the law in force in the country of installation.
•
In order for the automation unit to operate correctly, we recommend carrying out periodical maintenance on it, as indicated in this
manual.
•
Topp informs the user that, in accordance with art. 8 of ministerial decree no. 38 of 22.1.2008, the owner of the system is responsible
for adopting all necessary measures to maintain the safety features set out in applicable legislation, observing the instructions for
maintenance and use provided by the manufacturer of the device and by the company that carried out the installation.
•
The use of the actuator allows to control automatically the opening and closing of the window according to the type of control device
installed.
TECHNICAL DESCRIPTION -3
(1) Service of limited duration according to EN 60034
(2) Tolerance on the precision of limit switch tripping at output: +/- 10mm
Summary of Contents for C260
Page 2: ......
Page 4: ...INSTALLATION AND USE INSTRUCTIONS 4 C260 EC DECLARATION OF INCORPORATION ...
Page 9: ...C260 TECHNICAL DESCRIPTION 3 INSTALLATION AND USE INSTRUCTIONS 9 COMPONENTS A B C D E ...
Page 10: ...INSTALLATION AND USE INSTRUCTIONS 10 3 TECHNICAL DESCRIPTION C260 COMPONENTS DIMENSIONING ...
Page 25: ...ISTRUZIONI PER L INSTALLAZIONE E L USO 25 C260 5 INSTALLATION INSTRUCTIONS FIGURE ...
Page 28: ...ISTRUZIONI PER L INSTALLAZIONE E L USO 28 5 INSTALLATION INSTRUCTIONS FIGURE C260 ...
Page 30: ...INSTALLATION AND USE INSTRUCTIONS 30 C260 6 ELECTRICAL CONNECTIONS ...
Page 31: ......