9
Installation
Water source
1. Connect water inlet of pressure washer to running water outlet with water pipe,
and tighten them with clamps
2. Install water strainer if necessary at the pump entrance, conical surface should
be outside
Notice
!
·
Use clean water
·
Ensure original water pressure not lower than 25PSI
·
Ensure original flow rate should be at least 1.2 times of that rated inlet water
flow rate of the pressure washer
Add Engine Oil
1.
Place the generator on a flat, level surface.
2.
Remove OIL FILL CAP / DIPSTICK to add oil, for first use engine oil capacity
added is about
0.9
L.
3.
Add engine oil and reinstall OIL FILL CAP / DIPSTICK.
4.
Check engine oil level for each use and add as needed.
Oil Fill Cap/ Dipstick
Filler Hole
For engine:
For pump:
For first use please put off the protective bolt on
the pump with a 17mm wrench
Add about 0.3L 30 # wear-resistant oil, oil level
to the middle position of observation pole, screw
up with the respirator.
Observation pole
Hole for adding oil