GTCOM2 User manual
35 |
E N
Figure 56 GSM Communication> CMS Reporting window
6.3
General system options programming
The system comes equipped with internal real-time clock (RTC) with battery that keeps
track of the current date and time. Once the system is up and running, the user must set the
correct date and time, otherwise the system will not operate properly. SERA2 software
provides the ability to select the Time Zone and The user may also choose Set module time
from PC, which instantly provides the exact PC time. When the system is connected to the
monitoring station via IP connection the date and time will be automatically synchronized with
the monitoring station. It is possible to select automatically time synchronization with: GSM
Modem, Cloud Server or disable it.
Figure 57 Clock, time Zone and clock synchronization.
Sera2> System Options> General System Options
If the module has been connected first time to the power supply, or power supply has been disconnected for a long time, the time of the
module should be set again.
The module can send a trouble report and restrict arming if some of selected troubles [Restrict ARM] exist during close event.
System Options > General system Options
The general system options settings let you control system options, system general
settings, systems timers, let you program iButton keys and reset the module.