WARNING
FEATURES
SPECIFICATIONS
INSTALLATION INSTRUCTIONS
Model: TDOS5
Occupancy/ Vacancy
Sensor Switch
WIRING DIRECTIONS
Use copper wires only.
Turn the POWER OFF at the circuit breaker before
installing the Sensor Switch.
Read and understand these instructions before installing. This device is intended for
installation in accordance with the National Electric Code and local regulations. It is
recommended that a qualified electrician performs this installation.
Use wires with a minimum temperature rating of 75ºC (167ºF)
2
3
1
1. Remove the wall plate.
2. Remove existing switch from wall box and prior to disconnecting wires, identify
the wires and label as needed.
3. Remove wires from existing switch.
4. Follow the diagram below to reconnect the TDOS5 sensor switch.
WARNING: The white wire you see in the wall box is not
always the neutral wire. Verify whether the
power enters the wall or ceiling box first. If
you have only 2 wires, this switch will not
work. You will need model # TDOS5-J instead
Power must enter
the
wall box first, not fixture.
Neutral
Ground
Ceiling box
Wall box
Load
Ground
Neutral
Hot
Load
POWER
The TDOS5 uses advanced passive infrared sensor to detect heat emitted motion. The
sensor switch can turn on a load and keep it on as long as it detects motion. The sensor will
automatically shut off the load at the end of the selected time delay. The countdown of the
selected time delay starts after the last motion detected. The sensor is customizable with
dials that can adjust Time Delay and detection Range and a switch to change between
Occupancy/ Vacancy modes.
The control panel cover is also the push button on the switch. Remove the push-button
cover plate by prying from the bottom of the push-button and pulling outward.
REMOVING COVER PANEL
There must be a neutral
wire for switch to work
After the one mintue warm-up, adjust the knobs to your desired sensitivity range and time
delay. The sensors are factory preset to allow for quick installation in most applications.
Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4)
Note: Turn toward right for greater room space. Turn toward left to avoid
false alert in smaller rooms and near doorways or heat source.
Time Delay Knob
Detection Range Knob (Sensor Sensitivity)
Note: There is a 60-second warm-up period after each power
reset (such as a power outtage).
LED Indicator
PIR Sensor
Detection Range
adjustment knob
Time Delay
adjustment knob
ADJUSTMENT
NOTICE:
Once you have completed the wiring, we recommend that you turn on the power
to test and adjust the settings to your desire
before installing the wallplate
. The adjustment
dials are located under the face cover, which can be removed by prying the cover off with a
small flathead screwdriver.
Switch Type..............................................................................Single Pole
Voltage ....................................................................…............120V, 60Hz
Incandescent.....................................................................................500W
Fluorescent......................................................................................500VA
Motor .......................................................................................……..1/4Hp
Time Delay.......................................................................15Sec to 30Mins
Operation Temperature................................ 32° F--131° F(0 °C to 55 °C)
PIR Coverage.........................1200 sq.ft. (up to 40’ in front of the sensor)
OFF OCC VAC