Occupancy/ Vacancy

Sensor Switch

WIRING DIRECTIONS 

Use copper wires only.

Turn the POWER OFF at the circuit breaker before 

installing the Sensor Switch.

Read and understand these instructions before installing. This device is intended for

installation in accordance with the National Electric Code and local regulations. It is

recommended that a qualified electrician performs this installation. 

Use wires with a minimum temperature rating of 75ºC (167ºF)

2

3

1

1. Remove the wall plate.

2. Remove existing switch from wall box and prior to disconnecting wires, identify

    the wires and label as needed.

3. Remove wires from existing switch.

4. Follow the diagram below to reconnect the TDOS5 sensor switch.

WARNING: The white wire you see in the wall box is not

 

 

always the neutral wire. Verify whether the

 

 

power enters the wall or ceiling box first. If

 

 

you have only 2 wires, this switch will not

 

 

work. You will need model # TDOS5-J instead

Power must enter

 

the

wall box first, not fixture.

Neutral

Ground

Ceiling box

Wall box

Load

Ground

Neutral

Hot

Load

POWER

The TDOS5 uses advanced passive infrared sensor to detect heat emitted motion. The

sensor switch can turn on a load and keep it on as long as it detects motion. The sensor will

automatically shut off the load at the end of the selected time delay. The countdown of the

selected time delay starts after the last motion detected. The sensor is customizable with

dials that can adjust Time Delay and detection Range and a switch to change between

Occupancy/ Vacancy modes.

The control panel cover is also the push button on the switch. Remove the push-button

cover plate by prying from the bottom of the push-button and pulling outward.

REMOVING COVER PANEL

There must be a neutral

wire for switch to work

After the one mintue warm-up, adjust the knobs to your desired sensitivity range and time

delay. The sensors are factory preset to allow for quick installation in most applications. 

Default position: 15 Seconds (Test mode)

Adjustable: from 15 Seconds to 30 Minutes (clockwise)

Default position: Center at 65%

Adjustable: 30% (Position 1) to 100% (Position 4)

Note: Turn toward right for greater room space. Turn toward left to avoid

false alert in smaller rooms and near doorways or heat source.

Time Delay Knob

Detection Range Knob (Sensor Sensitivity)

Note: There is a 60-second warm-up period after each power

reset (such as a power outtage).

LED Indicator

PIR Sensor

Detection Range

adjustment knob

Time Delay

adjustment knob

ADJUSTMENT

NOTICE: 

Once you have completed the wiring, we recommend that you turn on the power

to test and adjust the settings to your desire 

before installing the wallplate

. The adjustment

dials are located under the face cover, which can be removed by prying the cover off with a

small flathead screwdriver.

Switch Type..............................................................................Single Pole

Voltage ....................................................................…............120V, 60Hz

Incandescent.....................................................................................500W

Fluorescent......................................................................................500VA

Motor .......................................................................................……..1/4Hp

Time Delay.......................................................................15Sec to 30Mins

Operation Temperature................................ 32° F--131° F(0 °C to 55 °C)

PIR Coverage.........................1200 sq.ft. (up to 40’ in front of the sensor)