Topgreener TDOS5-JM Installation Instructions Download Page 1

WARNING

FEATURES

SPECIFICATIONS

INSTALLATION INSTRUCTIONS

Model: TDOS5-JM

Occupancy/ Vacancy

CDS Sensor Switch

WIRING DIRECTIONS: 

Use copper wire only.

Turn the POWER OFF at the circuit breaker before 

installing the Sensor Switch.

Read and understand these instructions before installing. This device is intended for

installation in accordance with the National Electric Code and local regulations. It is

recommended that a qualified electrician performs this installation. 

Use wires with a minimum temperature rating of 75ºC (167ºF)

2

3

1

1. Remove the wall plate.

2. Remove existing switch from wall box and prior to disconnecting wires,

    identify the wires and label as needed.

3. Remove wires from existing switch.

4. Follow the diagram below to reconnect the TDOS5-JM sensor switch.

WARNING: The white wire you see in the wall box is not

 

 

always the neutral wire. Verify whether the

 

 

power enters the wall or ceiling box first

If 

power enters 

the wall box first,

then wire the TDOS5-JM this way

If power enters the ceiling box first,

then wire the TDOS5-JM this way

Hot

Power

Neutral

Ground

Ceiling box

Wall box

Load

Hot

Load

Ground

Reversible

Neutral

Ground

Ceiling box

Wall box

Load

Ground

Neutral

Hot

Load

POWER

Hot

The sensor switch can automatically turn a load on (or manually be turned on) and stay

on as long as the sensor detects occupancy. After no motion is detected within the

selected time delay, the load turns off automatically. This device features a learning

capability; it will learn your on/off habits based on your usage during different ambient

light levels, then automatically operate the lights based on the usage patterns.

Voltage ....................................................................…............120V, 60Hz

Tungsten.........................................................................................1800W

Resistive..............................................................................................10A

Electronic Ballast ..................................................................................5A

Motor .......................................................................................…… 1/6Hp

Time Delay......................................................................15Sec to 30Mins

Operation Temperature................................ 32° F--104° F(0 °C to 40 °C)

PIR Coverage.........................1200 sq.ft. (up to 40’ in front of the sensor)

Remove the cover panel with a flathead screwdriver. Find the slots at the

bottom left or right of the panel cover and gently pry the panel cover off.

LED Indicator

Fresnel Lens

On/ Off and 

Program Button 

REMOVING COVER PANEL: