INSTALLATION INSTRUCTIONS 

 TD0S5-

J

OCCUPANCY/VACANCY 

(2-IN-1) 

SENSOR SWITCH 

Voltage .........................................................................

...

.

...

120VAC,60Hz

 

Incandescent ................................................................................

........

500W

 

Fluorescent

/Ballast

............................

..

500VA

@

120VAC/1000VA

@277VAC

Motor  ........................................................................................

.......1

/

4

H

P

 

Time Delay ................................................................

.......1

5Sec to 30Mins

 

Light Level. .................................................................

.......

30 Lux--Daylight

 

Operation Temperature ......................................................

.....

32 F

-131 F

0

The  passive  infrared  sensor  work

s

  by  detecting  the  difference 

between  heat  emitted  from  the  human  body  in  motion  and  the 
background space. The sensor switch can turn a load on and hold it as 
long as the sensor detects occupancy. After no motion is detected for the 
set time delay,  the load  turned  off automatically.

 

The  sensor switch  has 

one  relay  (equal  to  single  pole  switch),  also  includes  Ambient  Light 
Level Sensor. 

C

overage 

A

rea

The coverage  range of the sensor switch is specified and  illustrated in 
Figure 1. Large objects and some transparent barriers like glass 
windows  will  obstruct  the  sensor'

s

  view  and  prevent  detection, 

causing the light to turn off  even

 if

 someone is still in the detection area

- 01-

Figure 1 

Figure 2 

Figure 3 

-02-

Description

 

OFF

 

Left

 

Circuit is permanently 

opened. 

( switched off) 

Center

 

Occupancy Mode: 

Automatic On, automatic 

Off 

after set time delay. 

VAC

 

Right

 

Figure 4 

P

ush-

B

utton

 on Reaction

None

 

Manually toggles

 

On

I

Off load.

 

Manually toggles

 

On/Off the load.

 

Time Delay knob 

Default position: 15 Seconds (Test mode) 
Adjustable: from 15 Seconds to 30 Minutes (clockwise)

 

Sensor Sensitivity Range Knob

 

Default position: Center at 65% 

Adjustable:  30% (Position 1) to 100% (Position 4) 

Note: 

Turn toward right for greater room space. 

Turn toward left to avoid false alert in smaller room and near 

the door way or heat source. 

-03-

1.
2.

The black wires on the sensor are hot and load interchangeable

.

Connect lead wires as wiring diagram (see Figure 2): 

One B

lack

 

lead

 

to 

Hot or Load,

 

The other Black

 lead to 

Load or Hot

, Green

 

lead to Ground.

3.

Gently position wires in wall box, attach sensor switch to the box.

4.

Mount device "TOP"

 

up.

5.

Restore power at circuit breaker or fuse

.

 

W

ait 

three

 

minute

s for

the sensor complete its initial run.

Note:

 The sensor needs to be charged for 3 minutes in the first

use. Please do not press any button and make any adjustment in

this period of them for the sensor to work properly.

6.

Remove the small cover plate.  (Illustrated

 in

 Figure 3)

7.

Locate the adjustment knobs on the control panel to test

 

and

change setting

.(

I

llustrated 

in

 Figure 3)

8.

Replace the small cover plate after testing and 

setting

.

9.

Attach the wallplate.

DESCRIPTION

ION

I

INSTALLATION

ION

SAFETY WARNING:

:

 

Read and understand these instructions

before installation. This device is intended for installation in 

accordance with the National Electrical Code and local 

regulations. 

I

t is recommended that a qualified electrician 

perform this installation. Make sure to turn off the circuit 

breaker or fuse(s) and test that the power is off before wiring 

the device.

 

Note: 

Green wire on the sensor must be connected to Ground 

or Neutral for the sensor to work proper

l

y.

W

iring Diagram:

ADJUSTMENT

 

Band Switch 

D

escription

OCC

 

TDOS5-

J

 

SPECIFICATIONS

A

mbient 

Light

 

L

evel 

Adjustment

.

Note:

  Please  complete  Initial  Run  (3  minutes)  before  adjusting 

ambient light level

.

1.

Set the Band Switch to VAC.

Switch Type .......................................................

.

.........................Single Pole