Basic Operation
12
Setting for Optical communications with total station
The following settings is prerequisites for the optical communications to take place between the
total station (or an application program) and RC-2RW.
●
When communicating by using [EXT.LINK] of the application software
(AP-L1 communication mode).
1
Select Communication Path to RC in the program [EXT.LINK] .
Operation:
Main menu - Program Modes [F1](Prog) - [F2](EXT.LINK) - [F2](Setting) - [F1](CABLE /
RADIO MODEM / RC)
2
Set Parameter for RC.
Operation:
Main menu - Program Modes [F1](Prog) - [F2](EXT.LINK) - [F2](Setting) - [F3](RC)
Main menu - Parameters Setting Modes [F6](Para) - [F2](communication) - [F3](Set RC)
3
Execute the External Link.
Operation:
Main menu - Program Modes [F1](Prog) - [F2](EXT.LINK) - [F1](Execute)
●
When communicating without using [EXT.LINK] (GTS communication
mode).
1
Select Communication Path to RC in the Parameters Setting Mode.
Operation:
Main menu - Parameters Setting Modes [F6](Para) - [F2](communication) - [F1](Serial Port)
2
Set the parameters in the Parameters Setting Mode. (Refer to Table of item to be set showen
as follows.)
Operation:
Main menu - Parameters Setting Modes [F6](Para) - [F2](communication) - [F3](Set RC)
Set the parameters in Setting Mode.
Refer to Table of item to be set in Setting Mode.
●
When communicating by using Bluetooth, refer to the manual of Data Collector’s application
software.
●
When communicating by means of RS-232C.
Connect a data collector to be used to the serial RS-232C connector of the RC-2RW, and set the
items as follows.
B.Rate
4800
Data.L
8
Parity
none
Stop Bit
1
Setting Parameters in total station
Setting Parameters in RC-2RW
Setting Parameters of Communication port in Data Collector