INSTRUCTION MANUAL
Level Sensor
LS-80A/B/G/L
Thank you for purchasing the TOPCON Level Sensor LS-80A/B/G/L.
For the best performance of the instruments, please read these instructions care-
fully and keep them in a convenient location for future reference.
HANDLING PRECAUTIONS
Guarding the instrument against shock
When transporting the instrument, provide some protection to minimize risk of
shock. Heavy shock may affect beam accuracy.
DISPLAY FOR SAFE USE
In order to encourage the safe use of products and prevent any danger to the
operator and others or damage to properties, important warnings are put on the
products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays and
icons before reading the “Safety Cautions” and text.
• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to buildings or equipment and furniture.
SAFETY CAUTIONS
EXCEPTIONS FROM RESPONSIBILITY
NOMENCLATURE
DISPLAY
AUTO-CUT OFF FUNCTION
The power will be turned off automatically after detecting no laser beam for more than approx. 30
minutes. (To turn on the level sensor, press the power switch again.)
*1, 2 For more information about the warning displays of above *1 and *2, refer to instruc-
tion manual of each rotating laser.
REPLACING BATTERY
1
Keep pushing the battery cover in 1 direction
,
and then try to
slide the cover in 2 direction.The cover does not move but it
will be open.
2
Take out the battery and place a new one into the battery box.
3
Press the lid down and click to close.
• Replace all 2 batteries with new ones at the same time. Do not mix used and new batteries, and do not
mix different types of batteries together.
• Use alkaline dry cells. (Dry cells for movement confirmation are packed in shipment.)
Nickel hydrogen dry cells and nickel cadmium dry cells can be used too, but the operating time is dif-
ferent from the time of alkaline dry cells.
• Generally, performances of dry cell deteriorate temporarily in low temperature, but recover in normal
temperature.
DETECTIVE RANGE
EXAMPLE OPERATIONAL
31351 90071
Display
Meaning
WARNING
Ignoring or disregard of this display may lead to death or serious
injury.
CAUTION
Ignoring or disregard of this display may lead to personal injury
or physical damage to the instrument.
WARNING
1) There is a risk of fire,electric shock or physical harm if you attempt to disassemble
or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer,only!
2) Risk of fire or electric shock.
Do not use a wet battery or charger.
3) Battery can cause explosion or injury.
Do not dispose in fire or heat.
4) The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
CAUTION
1) Do not allow skin or clothing to come into contact with acid from the batteries,if this
does occur then wash off with copious amounts of water and seek medical advice.
1) The user of this product is expected to follow all operating instructions and make
periodic checks of the product’s performance.
2) The manufacturer,or its representatives, assumes no responsibility for results of a
faulty or intentional usage or misuse including any direct,indirect,consequential dam-
age,and loss of profits.
3) The manufacturer,or its representatives,assumes no responsibility for consequential
damage,and loss of profits by any disaster,(an earthquake, storms, floods etc.).
A fire,accident,or an act of a third party and/or a usage any other usual conditions.
4) The manufacturer,or its representatives,assumes no responsibility for any damage,and
loss of profits due to a change of data,loss of data,an interruption of business etc., caused
by using the product or an unusable product.
5) The manufacturer,or its representatives,assumes no responsibility for any dam-
age,and loss of profits caused by usage except for explained in the user manual.
6) The manufacturer,or its representatives,assumes no responsibility for damage
caused by wrong movement,or action due to connecting with other products.
FCC
NOTE:
This equipment has been tested and found to comply with limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm-
ful interference in a residential installation. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
Declaration of Conformity
Model Number:
LS-80A/B/G/L
Trade Name:
TOPCON CORPORATION
Manufacturer
Name:
TOPCON CORPORATION
Address:
75-1, Hasunuma-cho, Itabashi-ku, Tokyo, 174-8580 JAPAN
Country:
JAPAN
U.S.A. Representative
Responsible party:
TOPCON POSITIONING SYSTEMS,INC.
Address:
7400 National Drive Livermore, CA94551, U.S.A
Telephone number:
925-245-8300
http://www.topcon.co.jp
GLOBAL GATEWAY http://global.topcon.com/
Please see the attached address list or the following website for contact addresses.
©
2010 TOPCON CORPORATION
ALL RIGHTS RESERVED
Detective precision switch
Two leveling precision options are
available, normal precision and
high precision. By pressing this
switch, the precision options are
switched alternately. Confirm the
precision choice by the indicator.
(Normal precision is set when
turning on the power switch.)
Buzzer sound switch
(Quiet/Loud/OFF)
Beam receiving window
Indicator
Also located on the back side
Index
Power switch
Buzzer speaker
Higher than datum position
(Buzzer sound:High frequent beep sound)
Move the sensor downward.
Height alert warning of rotating laser
*1
(Except for LS-80G)
A flash and a buzzer sound signifies
that the height alert function of rotating
laser is operating.
Level sensor can detect the signal of height
alert warning of the rotating laser.
(This function is not usable to the rotating
laser which does not have the height alert
and the function to output alarm signal.)
High precision mode
Normal precision mode
Datum position
(Buzzer sound:Continuous beep sound)
Lower than datum position
(Buzzer sound:Low frequent beep sound)
Move the sensor upward.
Battery remaining display
Indicates the battery remaining of level
sensor as follows.
Rotating laser battery warning
*2
(Except for LS-80G)
A flash shows that the rotating laser
power is low.
The level sensor can detect the rotating laser
battery warning.
(This function is not usable to the rotating laser
which does not have the function to output alarm
signal.)
Note:The warning displays *1 and *2 are the func-
tions that the level sensor detects alarm signal
from the rotating laser.
The level sensor can be canceled the alarm detec-
tion from the rotating laser.
To be canceled the detection; Press the power
switch while pressing the buzzer sound switch
when powering on.
Battery is sufficient.
The power is low, but laser
is still usable.
Dead battery.
Replace the dry battery
with new one.
1
2
SPECIFICATIONS
About measuring range, refer to instruction manual
of each rotating laser.
Detective range
50mm (2.0 in)
Detective precision
High precision
: ±1mm (±0.04 in)
Normal precision : ±2mm (±0.08 in)
Detective beam indication
Liquid crystal
: Both sides (LS-80A/G/L)
: Front side only (LS-80B)
Buzzer (LS-80A/B/G/L)
Power source
2×AA size dry cell batteries
*Batteries included in the package are to
confirm the initial operation.Please replace the
batteries provided with new batteries as soon
as possible.
Voltage
DC 3V
The time for auto-cut off
Approx. 30 min.
Waterproof property / dust resistance
JIS protection grade IP66
Operating temperature
–20°C to +50°C (–4°F to +122°F)
Continuous operating time
Alkaline manganese dry batteries
Approx. 120hours
Dimensions
146 (l) × 76 (w) × 26 (h) mm
(5.7 (l) × 2.9 (w) × 1.0 (h) in)
Weight
0.19 kg (0.41 lbs) (including dry batteries)
LS-80L • 8024962/2019-10-16/en, de • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com