background image

INSTRUCTION MANUAL

Level Sensor

LS-80A/B/G/L

Thank you for purchasing the TOPCON Level Sensor LS-80A/B/G/L.
For the best performance of the instruments, please read these  instructions care-
fully and keep them in a convenient location for  future reference.

HANDLING PRECAUTIONS

Guarding the instrument against shock

When transporting the instrument, provide some protection to minimize risk of 

shock. Heavy shock may affect beam accuracy.

DISPLAY FOR SAFE USE

In order to encourage the safe use of products and prevent any danger to the 

operator and others or damage to properties, important warnings are put on the 

products and inserted in the instruction manuals.

We suggest that everyone understand the meaning of the following displays and 

icons before reading the “Safety Cautions” and text.

• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to buildings or equipment and furniture.

SAFETY CAUTIONS

EXCEPTIONS FROM RESPONSIBILITY

NOMENCLATURE

DISPLAY

AUTO-CUT OFF FUNCTION

The power will be turned off automatically after detecting no laser beam for more than approx. 30 
minutes. (To turn on the level sensor, press the power switch again.)

*1, 2 For more information about the warning displays of above *1 and *2, refer to instruc-

tion manual of each rotating laser.

REPLACING BATTERY

1

Keep pushing the battery cover in 1 direction

,

 and then try to 

slide the cover in 2 direction.The cover does not move but it 
will be open.

2

Take out the battery and place a new one into the battery box.

3

Press the lid down and click to close.

• Replace all 2 batteries with new ones at the same time. Do not mix used and new batteries, and do not 

mix different types of batteries together.

• Use alkaline dry cells. (Dry cells for movement confirmation are packed in shipment.)

Nickel hydrogen dry cells and nickel cadmium dry cells can be used too, but the operating time is dif-
ferent from the time of alkaline dry cells.

• Generally, performances of dry cell deteriorate temporarily in low temperature, but recover in normal 

temperature.

DETECTIVE RANGE

EXAMPLE OPERATIONAL

31351 90071

Display

Meaning

 WARNING

Ignoring or disregard of this display may lead to death or serious 
injury.

 CAUTION

Ignoring or disregard of this display may lead to personal injury 
or physical damage to the instrument.

 WARNING

1) There is a risk of fire,electric shock or physical harm if you attempt to disassemble 

or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer,only!

2) Risk of fire or electric shock. 

Do not use a wet battery or charger.

3) Battery can cause explosion or injury.

Do not dispose in fire or heat.

4) The short circuit of a battery can cause a fire. 

Do not short circuit battery when storing it.

 CAUTION

1) Do not allow skin or clothing to come into contact with acid from the batteries,if this 

does occur then wash off with copious amounts of water and seek medical advice.

1) The user of this product is expected to follow all operating instructions and make

periodic checks of the product’s performance.

2) The manufacturer,or its representatives, assumes no responsibility for results of a 

faulty or intentional usage or misuse including any direct,indirect,consequential dam-
age,and loss of profits.

3) The manufacturer,or its representatives,assumes no responsibility for consequential 

damage,and loss of profits by any disaster,(an earthquake, storms, floods etc.). 
A fire,accident,or an act of a third party and/or a usage any other usual conditions.

4) The manufacturer,or its representatives,assumes no responsibility for any damage,and 

loss of profits due to a change of data,loss of data,an interruption of business etc., caused 
by using the product or an unusable product.

5) The manufacturer,or its representatives,assumes no responsibility for any dam-

age,and loss of profits caused by usage except for explained in the user manual. 

6) The manufacturer,or its representatives,assumes no responsibility for damage 

caused by wrong movement,or action due to connecting with other products.

FCC

NOTE:

This equipment has been tested and found to comply with limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm-
ful interference in a residential installation. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which 

the receiver is connected.

- Consult the dealer or an experienced radio / TV technician for help.

Declaration of Conformity

Model Number:

LS-80A/B/G/L

Trade Name:

TOPCON CORPORATION

Manufacturer

Name:

TOPCON CORPORATION

Address:

75-1, Hasunuma-cho, Itabashi-ku, Tokyo, 174-8580 JAPAN

Country:

JAPAN

U.S.A. Representative

Responsible party:

TOPCON POSITIONING SYSTEMS,INC.

Address:

7400 National Drive Livermore, CA94551, U.S.A

Telephone number:

925-245-8300

http://www.topcon.co.jp

GLOBAL GATEWAY  http://global.topcon.com/

Please see the attached address list or the following website for contact addresses.

©

2010 TOPCON CORPORATION

    ALL RIGHTS RESERVED

Detective precision switch

Two leveling precision options are 
available, normal precision and 
high precision. By pressing this 
switch, the precision options are 
switched alternately. Confirm the 
precision choice by the indicator. 
(Normal precision is set when 
turning on the power switch.)

Buzzer sound switch

(Quiet/Loud/OFF)

Beam receiving window

Indicator

Also located on the back side 

Index

Power switch

Buzzer speaker

Higher than datum position

(Buzzer sound:High frequent beep sound)
Move the sensor downward.

Height alert warning of rotating laser

*1

(Except for LS-80G)

A flash and a buzzer sound signifies
that the height alert function of rotating
laser is operating.
Level sensor can detect the signal of height 
alert warning of the rotating laser.
(This function is not usable to the rotating 
laser which does not have the height alert 
and the function to output alarm signal.)

High precision mode

Normal precision mode

Datum position

(Buzzer sound:Continuous beep sound)

Lower than datum position

(Buzzer sound:Low frequent beep sound)
Move the sensor upward.

Battery remaining display

Indicates the battery remaining of level 
sensor as follows.

Rotating laser battery warning

*2

(Except for LS-80G)

A flash shows that the rotating laser
power is low.
The level sensor can detect the rotating laser 
battery warning.
(This function is not usable to the rotating laser 
which does not have the function to output alarm 
signal.)
Note:The warning displays *1 and *2 are the func-
tions that the level sensor detects alarm signal 
from the rotating laser.
The level sensor can be canceled the alarm detec-
tion from the rotating laser.
To be canceled the detection; Press the power 
switch while pressing the buzzer sound switch 
when powering on.

Battery is sufficient.

The power is low, but laser 
is still usable.

Dead battery.
Replace the dry battery 
with new one.

1

2

SPECIFICATIONS

About measuring range, refer to instruction manual 
of each rotating laser.

Detective range

50mm (2.0 in)

Detective precision

High precision

 : ±1mm (±0.04 in)

Normal precision  : ±2mm (±0.08 in)

Detective beam indication

Liquid crystal

: Both sides (LS-80A/G/L)

: Front side only (LS-80B)

Buzzer (LS-80A/B/G/L)

Power source

2×AA size dry cell batteries

*Batteries included in the package are to 

confirm the initial operation.Please replace the

 batteries provided with new batteries as soon

 as possible.

Voltage

DC 3V

The time for auto-cut off

Approx. 30 min.

Waterproof property / dust resistance

JIS protection grade IP66

Operating temperature

–20°C to +50°C (–4°F to +122°F)

Continuous operating time

Alkaline manganese dry batteries

Approx. 120hours

Dimensions

146 (l) × 76 (w) × 26 (h) mm

(5.7 (l) × 2.9 (w) × 1.0 (h) in)

Weight

0.19 kg (0.41 lbs) (including dry batteries)

LS-80L • 8024962/2019-10-16/en, de • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com

Reviews: