4-3
4 STANDARD MEASUREMENT MODE
2) Setting a Horizontal Angle from the Keys
Make sure the mode is Angle measurement.
4.1.4 Vertical Angle Percent Grade(%) Mode
Make sure the mode is Angle measurement.
Operating procedure
Operation
Display
1
Collimate the target.
Collimate
2
Press [F6](
↓
) key to get the function as on
page 2, and press [F2](HSET) key.
3
Input the required horizontal angle.
*1)
For example:70
°
20'30"
[F6]
[F2]
Input
value
4
Press [ENT] key. *2)
When completed, normal measuring from the
required Horizontal angle is possible.
[ENT]
*1)To revise wrong value, move cursor with [F6](BS) key, or input from the beginning by [F1](EXIT) key to
correct value.
*2)With wrong input value (for example 70'), setting will not be completed. Input again from step
3
.
Operating procedure
Operation
Display
1
Press [F6](
↓
) key to get the function as on
page 2.
[F6]
2
Press [F4](V/%) key. *1)
[F4]
*1) Every time pressing the [F4](V/%) key, the display mode switches.
V : 90
°
10'20"
HR: 120
°
30'40"
SD HD NEZ 0SET HOLD P1
↓
TURN HSET R/L V/% TILT P2
↓
H-SET
HR:
H-SET
HR:70.203
EXIT BS
V : 90
°
10'20"
HR: 70
°
20'30"
SD HD NEZ 0SET HOLD P1
↓
V : 90
°
10'20"
HR: 120
°
30'40"
SD HD NEZ 0SET HOLD P1
↓
TURN HSET R/L V/% TILT P2
↓
V%: -0.30 %
HR: 120
°
30'40"
TURN HSET R/L V/% TILT P2
↓
Summary of Contents for GTS-821A, GTS-822A, GTS-823A, GTS-825A
Page 2: ......
Page 120: ...11 4 11 SETTING ATMOSPHERIC CORRECTION...
Page 121: ...11 5 11 SETTING ATMOSPHERIC CORRECTION...
Page 143: ......