MINTER Configuration
P/N 7010-1004
3-47
FN Key Mode parameter
Use these two radio buttons to program
how the receiver reacts when pressing the
FUNCTION
key.
• LED blink mode switch – pressing
FUNCTION
toggles between
the MINTER’s normal/extended information modes and start/
stop data recording of Static survey.
–
FUNCTION
pressed for less than 1 second: changes the
information mode (Normal or Extended Information Modes).
–
FUNCTION
pressed for 1 to 5 seconds: starts or stops data
recording (Static post-processing mode).
• Occupation mode switch – pressing
FUNCTION
(less than one
second) will insert a message into the corresponding log file,
indicating that the survey type changed from static to kinematic,
or vice versa. If the REC LED blinks green, the current mode is
dynamic, if it blinks orange, the current mode is static. For more
details, see Table 1-2 on page 1-13 and refer to the
PC-CDU
Reference Manual
.
Initial Data Collection Dynamic Mode parameter
These radio
buttons specify the starting occupation type descriptor inserted at the
beginning of receiver files logged. Select Static or Kinematic to
specify that the corresponding log file starts with a static (STOP) or
kinematic (GO, Trajectory) occupation, respectively.
Data Recording Auto-start parameter
These radio buttons allow
the user to program the receiver’s behavior in the event of a power
failure.
Table 3-5 on page 3-47 describes the different scenarios available and
the results after power is restored to the receiver. “Specified file”
refers to the file name entered in the
Always append to file
field.
Summary of Contents for GR-5
Page 1: ... PERATORlS ANUAL ...
Page 2: ......
Page 4: ...ECO 4074 ...
Page 9: ...Table of Contents P N 7010 1004 v WEEE Directive C 2 Appendix D Warranty Terms D 1 Index ...
Page 10: ...Table of Contents GR 5 Operator s Manual Notes vi ...
Page 16: ...Preface GR 5 Operator s Manual Notes xii ...
Page 18: ...Introduction GR 5 Operator s Manual 1 2 Figure 1 1 GR 5 Receiver ...
Page 44: ...Introduction GR 5 Operator s Manual Notes 1 28 ...
Page 99: ...Configuring the Receiver Using TRU P N 7010 1004 3 27 Figure 3 24 Add New Message ...
Page 121: ...MINTER Configuration P N 7010 1004 3 49 Figure 3 42 MINTER Tab ...
Page 122: ...GR 5 Configuration GR 5 Operator s Manual 3 50 ...
Page 170: ...Troubleshooting GR 5 Operator s Manual Notes 6 12 ...
Page 188: ...GR 5 Operator s Manual Notes A 18 ...
Page 192: ...GR 5 Operator s Manual Notes B 4 ...
Page 196: ...GR 5 Operator s Manual Notes D 2 ...
Page 201: ......