![Toparc 038479 Manual Download Page 9](http://html1.mh-extra.com/html/toparc/038479/038479_manual_1127883009.webp)
9
MT-125 / AT-125
EN
GOUGING
039223 (x1)
039148 (x1)
039155 (x5)
039506 - 6 m
039513 - 12 m
Shield
Protective
shroud
Electrode
Diffuser
039254 (x1)
Tailpipe
029278 (x5)
105A
029285 (x5)
125A
125A TRI
AT-125 – COUPAGE :
CUT
039131 (x1)
039155 (x5)
038479 - 6 m
Shield
Protective
shroud
Tailpipe
Electrode
Diffuser
039292 (x1)
039162 (x5)
45A
039179 (x5)
65A
039186 (x5)
85A
039315 (x5)
45A
039322 (x1)
45A
PRECISION CUT
039216 (x1)
039339 (x1)
ohmic
039520 - 12 m
85A TRI
039148 (x1)
039155 (x5)
Shield
Electrode
Diffuser
039308 (x1)
Tailpipe
039193 (x5)
105A
039209 (x5)
125A
038479 - 6 m
Protective
shroud
039223 (x1)
039445 (x1)
ohmic
039520 - 12 m
125A TRI
CAUSE OF FAULT
Never wrap the welding leads around your body.
CONSUMABLES
Consumables have a limited lifetime and it is important to monitor their condition and to know when to replace them.
Visually : consumables melted or damaged, diameter of the holes inside the diffusers over 1.5mm, used electrodes,
melted pads…
Practically : poor cutting, difficulty to start the arc…
Do not leave consumables in the environment.
SHROUD
Tighten the shroud in order to ensure that all parts are locked in place. The diffuser must not be able to spin easily.
GAS
Use compressed air with oil and water filtered.