Topac HFZ05DV Operator'S Manual Download Page 4

b.

 Determine the size of the battery in Amp-Hour or Reserve Capacity. If the ratings are not 

printed on the battery, contact your local battery dealer for this information. These are the 

only ratings that can be used to determine length to charging time. 

c.

 Use the battery rating, the charge level of the battery, and amp setting to be used on the 

charger in the formula provided below. 

Amp Hour Rating of Battery × Percent of Charged Needed

× 1.25 = Hours to Charge 

Amp Setting Selected On Charger 

NOTE: The length of charge times are approximate and varies from the battery to 

battery. Always follow the battery manufacturer’s specific charging instructions. 

CHARGING 

NOTE: Before using the charger, please review all safety and connection directions. 

Failure to do so can damage battery and cause serious injury or death. 

AUTOMATIC CHARGE STAGE 

 

6                                                                                                                        7

•Connect the charger to battery per the operating instructions.

•Connect the charger to AC outlet.

•Select the appropriate charging mode for your batteries.

•If the charger does not detect a properly connected battery, the Reverse Polarity Indicator 

LED will light or the Error Code will appear on LCD display until such a battery is detected. 

Charging will not begin while the Reverse Polarity Indicator LED is on or the error code 

appears. When the charging begins, the charging process Icon on LCD display will appear.

•When charging is completed, unplug the charger from the AC outlet first and then disconnect 

the batteries with charger.

Automatic Micro Process Control Unit Charge:

Stage 1 - Diagnosis: Analyze if the battery can accept a charge or not, and then prevent 

charging from proceeding on the a defective battery;

Stage2- Desulphation: The charger can rescue most drained batteries with voltages up to a 

Min 1.5±0.5V

Stage 3 - Pre-charge: If the battery voltage is less than 12V, charge it at the smaller 

current,which will protect the battery better;

Stage 4 - Soft start: Charge the battery to the maximum current gradually and never sudden-

ly.

Stage 5 - CC1/CC2/CC3 (Constant Current): The charger automatically adjusts the current 

according to the battery status in constant current, which benefits the battery for a long life;

Stage 6- CV (Constant Voltage): The battery is charged to nearly full, and will top off at 14.6V 

DC;

Stage 7 - Resting: The charger will cut off with full charged statement, and achieves the high 

energy efficiency;

Stage 8-Recond: When it is fully charged and low to 12.8V within 2min, the charger will judge 

automatically.

Stage 9 - Restoring: The charger monitors a fully charged battery automatically. If the battery 

falls below 12.8V DC, the charger will restart from stage 4 to stage 7.

ADDITIONAL FEATURES
a. REVERSE POLARITY PROTECTION

The REVERSE POLARITY INDICATOR LED will light and the power will not be sent to 

output cables if a reverse connection is detected. 

b. SHORT CIRCUIT PROTECTION

This protection is triggered if the charger detects less than 0.5V across the clamps, and no 

power will be sent to output cables. Refer to Error Code of “Er1” in the section of TROUBLE-

SHOOTING ERROR CODES.

c. OVER-VOLTAGE PROTECTION

When the charger is set to charge in a different voltage than the detected voltage of the 

battery, this protection will be engaged. Refer to Error Code of “Er1” in the section of TROU-

BLESHOOTING ERROR CODES.

d. BATTERY DIAGNOTICS FUNCTION

The charger continuously monitors battery condition and may report certain charging failures 

as fault codes. Refer to Error Code of “Er1” and “Er2” in the section of TROUBLESHOOTING 

ERROR CODES. Conditions that cause the errors include: if the battery voltage does not rise 

appropriately during the charging process (indicating a shorted cell) or if the maximum 

charge time has been exceeded, etc.

e. BATTERY RECONDITIONING FUNCTION

If a battery is discharged deeply, it could become sulphated and unable to accept a charge. 

Reconditioning Function may help reverse the effects of sulphation and restore a batteries 

ability to accept a charge. If the charger detects a sulphated battery, it will automatically 

activate Battery Reconditioning Function. If successful, normal recharging will resume after 

the battery is desulphated. If unsuccessful at desulphating the battery, refer to Error Code of 

“Er2” in the section of TROUBLESHOOTING ERROR CODES.

Automatic Battery Charger features 9-stage, high-efficiency charging technology, built-in 

Micro process control IC that ensures fast, safe and complete charging of serviceable batteries.

High Frequency (Switch Mode) Smart Charging Stages

Summary of Contents for HFZ05DV

Page 1: ...ng instructions Read all instructions and follow them with each use of this product CONTENTS IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 2 3 L E N A P L O R T N O C OPERATING INSTRUCTIONS 4 TROUBLESHOOTING FAULT CODES 9 MAINTANANCE INSTRUCTIONS 8 8 A T A D L A C I N H C E T www topacdc com Amazon Store Facebook 1 ...

Page 2: ...ORE USING CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary marking on these products and on engine PERSONAL SAFETY PRECAUTIONS 1 Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid...

Page 3: ... e For negative grounded vehicle connect POSITIVE RED clamp from battery charger to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK clamp to vehicle chassis or engine block away from battery Do not connect clamp to carburetor fuel lines or sheet metal body parts Connect to a heavy gage metal part of the frame or engine block f For positive grounded vehicle connect NEGATIVE BLACK c...

Page 4: ...ery for a long life Stage 6 CV Constant Voltage The battery is charged to nearly full and will top off at 14 6V DC Stage 7 Resting The charger will cut off with full charged statement and achieves the high energy efficiency Stage 8 Recond When it is fully charged and low to 12 8V within 2min the charger will judge automatically Stage 9 Restoring The charger monitors a fully charged battery automat...

Page 5: ...shorten the setting time for the users convenience The housing of the charger is water resistant IP 65 The first digit 6 means protection of humans against the access to dangerous parts by means of a wire dust proof protection The second digit 5 means the protection against the stream of water 12 5 l min poured on the housing from any direction IP 65 apply to housing only not clamps and AC power l...

Page 6: ...on Facebook 10 11 Merci de sauvegarder ces instructions Ce manuel contient d importantes instructions de sécurité et d utilisation Lisez toutes les instructions et suivez les à chaque utilisation de ce produit CONSIGNES DE SÉCURITÉ IMPORTANTES 12 PRÉCAUTIONS DE SÉCURITÉ PERSONNELLES 12 MODE D EMPLOI 14 CONSIGNES D ENTRETIEN 18 DONNÉES TECHNIQUES 18 ...

Page 7: ... une réparation Un réassemblage incorrect peut entraîner un risque d électrocu tion ou d incendie 11 Pour réduire les risques d électrocution débranchez le chargeur de la prise de courant avant d effectuer un entretien ou un nettoyage La désactivation des commandes ne réduit pas ce risque 12 AVERTISSEMENT RISQUE DE GAZ EXPLOSIFS une TRAVAILLER À PROXIMITÉ D UNE BATTERIE AU PLOMB ACIDE EST DANGEREU...

Page 8: ...SQUE LA BATTERIE EST INSTALLÉE DANS LE VÉHICULE UNE ÉTINCELLE PRÈS DE LA BATTERIE PEUT CAUSER UNE EXPLOSION DE LA BATTERIE POUR RÉDUIRE LE RISQUE D UNE ÉTINCELLE PRÈS DE LA BATTERIE une Positionnez les cordons CA et CC afin de réduire les risques de dommages causés par le capot la porte ou les pièces mobiles du moteur b Restez à l écart des pales de ventilateur des courroies des poulies et d autre...

Page 9: ... la section des codes d erreur de recherche de panne ré FONCTION DE DIAGNOSTIC DE BATTERIE Le chargeur surveille en permanence l état de la batterie et peut signaler certaines défaillances de charge comme codes d erreur Reportez vous au code d erreur Er1 et Er2 dans la section des codes d erreur de recherche de panne Les conditions qui provoquent les erreurs sont les suivantes si la tension de la ...

Page 10: ...s complètement chargée après une charge de 24 heures La tension de la batterie est inférieure à 12V en 2 minutes après le chargement complet La température du chargeur est trop élevée La batterie est défectueuse Les pinces de batterie sont déconnectées de la batterie Les pinces de batterie sont connectées les unes aux autres Connectez la batterie fermement et correcte ment Confirmez que la tension...

Reviews: