background image

16 

UCA2

16

8-2. Request UCA status

VMC to UCA2

90h

05h

11h

03h

A9h

Request status

UCA2 to VMC

90h

05h

11h

03h

A9h

Idling

90h

05h

14h

03h

Ach

Disable

90h

06h

16h

01h

03h

B0h

Sensor Problem COIL 1

90h

06h

16h

02h

03h

B1h

Sensor Problem COIL 2

90h

06h

16h

03h

03h

B2h

Sensor Problem DROP IN 2

90h

06h

16h

04h

03h

B3h

Sensor Problem DROP IN 1

90h

06h

16h

05h

03h

B4h

Sensor Problem COIL 2

90h

06h

16h

06h

03h

B5h

Sensor Problem COIL 2

90h

05h

17h

03h

AFh

Fishing

90h

05h

18h

03h

B0h

Program Checksum Error

90h

05h

4Bh

03h

E3h

NAK

8-3. Get UCA Version

VMC to UCA2

90h

05h

11h

03h

A9h

UCA2 to VMC

90h

10h

03h

56h

31h

2Eh

30h

36h

2Dh

54h

48h

42h

34h

03h

00h

8-4. Accept Setting

VMC to UCA2

90h

06h

12h

01h

03h

ACh

Accepting channel 1

90h

06h

12h

02h

03h

ADh

Accepting channel 2

90h

06h

12h

08h

03h

B4h

Accepting channel 8

UCA2 to VMC

90h

05h

50h

03h

E8h       

ACK 

90h

05h

4Bh

03h

E3h       

NAK

Summary of Contents for UCA2

Page 1: ...Thank you for choosing TOP VME UCA2 Coin Acceptor User Guide...

Page 2: ......

Page 3: ...2 1 General 2 2 2 Electronic 2 2 3 Machine 2 3 Packing List 2 4 Dimension 3 5 Installation 4 5 1 Harness Application 4 5 2 I O Circuit 9 5 3 Installation Notes 11 6 Maintenance 13 7 Troubleshooting 1...

Page 4: ...s 8 3 Get UCA Version 16 8 4 Accept Setting 16 8 5 Inhibit Setting 17 8 6 Upgrade Start 17 8 7 Upgrade Finish 17 8 8 Upgrading 17 8 9 Upgrade Verify 18 8 10 Read Start 18 8 11 Read Finish 18 8 12 Read...

Page 5: ...ptance rate up to 96 or greater 1 2 Features Low power consumption Mechanical and electrical anti string functions Accepting speed up to 3 coins per second CS100 Coin dispenser supports UCA2 Remote co...

Page 6: ...3 2mm 2 2 Electronic Power Source 12V DC 10 Power Consumption Standby 0 05A 0 6W Operration Current 0 20A 2 4W Maximum 0 50A 6W Temperature Range Operating Temperature 0 C 60 C Storage Temperature 10...

Page 7: ...3 Coin Acceptor 3 4 Dimension Unit mm inch...

Page 8: ...Extension Cable CU R961 1 Purchase 7 RS232 12V DC Power WEL RMS03 5 5V TTL Data Communication WEL R7U06 8 NOTE Software download Please refer to the G BOX Operation manual for a guide step by step ho...

Page 9: ...5 Coin Acceptor 5 PIN NO COLOR PIN DEFINE PIN1 RED 12V DC PIN2 ORANGE GND PIN3 GREEN INHIBIT PIN4 YELLOW METER PIN5 BLUE CREDIT PIN6 X X WEL RMS03...

Page 10: ...IN DEFINE PIN1 YELLOW METER PIN2 GREEN INHIBIT PIN5 RED 12V DC PIN7 BLUE CREDIT PIN8 PURPLE X PIN9 ORANGE GND PIN NO COLOR PIN DEFINE PIN1 RED 12V DC PIN2 ORANGE GND PIN3 GREEN INHIBIT PIN4 YELLOW MET...

Page 11: ...7 Coin Acceptor 7 CU R961 1 PIN NO COLOR PIN DEFINE PIN1 YELLOW INHIBIT PIN2 GREEN INHIBIT PIN5 RED 12V DC PIN7 BLUE METER PIN8 PURPLE METER PIN9 ORANGE GND...

Page 12: ...8 UCA2 8 WEL R7U06 PIN NO PIN DEFINE PIN2 TXD PIN3 RXD PIN5 GND PIN NO COLOR PIN DEFINE PIN1 BLUE GND PIN6 WHITE VCC PIN7 BLACK RXD PIN8 PURPLE TXD...

Page 13: ...9 Coin Acceptor 9 5 2 I O Circuit Pulse Interface...

Page 14: ...10 UCA2 10 RS232 Interface...

Page 15: ...in Acceptor 11 5 3 Installation Notes Please follow the steps below to install the UCA2 1 Use four screws to fix bezel on the machine 2 Fix main base on bezel by mounting clips Mounting Clip Mounting...

Page 16: ...12 UCA2 12 Installation Precautions UCA2 is not supposed to be aslope over 3 To make sure UCA2 work smoothly install machine farther than 3 cm from metal items is recommended...

Page 17: ...ean the internal sensors regularly To clean the internal sensors 1 Remove bezel by releasing mounting clips and pulling it out 2 Release the clip and remove lower base cover plate and hood 3 Use a sof...

Page 18: ...1 Fast coil set error Call TOP or agents for technical support X X 2 Second coil set error Inspect for foreign objects in coin path and clean X X 3 Fish sensor error X X 4 Drop sersor error X X 5 Ret...

Page 19: ...fixed LNG 1 Data Length Total number of bytes from SYNC to checksum CMD 1 Command DATA 0 250 Data necessary for command omitted by CMD EXT 1 End code 03H fixed CS 1 checksum by SUM result method witho...

Page 20: ...1 90h 06h 16h 05h 03h B4h Sensor Problem COIL 2 90h 06h 16h 06h 03h B5h Sensor Problem COIL 2 90h 05h 17h 03h AFh Fishing 90h 05h 18h 03h B0h Program Checksum Error 90h 05h 4Bh 03h E3h NAK 8 3 Get UCA...

Page 21: ...VMC 90h 05h 50h 03h E8h ACK 90h 05h 4Bh 03h E3h NAK 8 6 Upgrade Start VMC to UCA2 90h 05h 139 03h 23h UCA2 to VMC 90h 05h 50h 03h E8h ACK 90h 05h 4Bh 03h E3h NAK 8 7 Upgrade Finish VMC to UCA2 90h 05...

Page 22: ...o UCA2 90h 05h 39 03h CS UCA2 to PC 90h 05h 50h 03h E8h ACK 90h 05h 4Bh 03h E3h NAK 8 11 Read Finish PC to UCA2 90h 05h 38 03h CS UCA2 to PC 90h 05h 50h 03h E8h ACK 90h 05h 4Bh 03h E3h NAK 8 12 Readin...

Page 23: ...Taiwan Top Vending Machine Electronics Co Ltd NO 11 Anzhong St Luzhu Dist Taoyuan City338 Taiwan R O C Phone 886 3 3115969 Fax 886 3 3115970 E mail sales topvme com tw Website www topvme com...

Page 24: ...Top Vending Machine Electronics Co Ltd www topvme com...

Reviews: