4
ATENCIÓ N – RIESGO DE INCENDIO O EXPLOSIÓ N DEBIDO A REFRIGERANTE INFLAMABLE
UTILIZADO. SIGA LAS INSTRUCCIONES DE MANIPULACIÓ N CON CUIDADO CONFORME A
LAS REGLAS DE LA MUNICIPALIDAD.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE.
SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX
RÈGLEMENTATION GOUVERNEMENTALE LOCAUX.
TECHNICAL SPECIFICATIONS
MODEL
DZW-1200
DZW-1500
DZW-1800
DZW-2000
Number of doors
2
Capacity (cu.ft)
15.3
18.2
21.4
30
Number
of
Shelves
2
HP
1/3
1/3
1/2
1/2
Electrical
110V/60HZ/1P
Amps
5.0
5.8
6.2
6.8
Temperature
Range
33-41 °F
Refrigerant
R290a
Dimensions
47.2”x32.5”x45.2”
59”x32.5”x45.2”
70.8”x32.5”x45.2”
79” x32.5”x45.2”
Shipping Weight
551
639
720
785
INSTALLATION
TRANSPORTATION
1.
To prevent the oil contained in the compressor from flowing into the cooling circuit,
it is necessary to always carry, store and handle the unit in a vertical position and
follow the instructions found on the packaging.
2.
If the unit was placed in a non-vertical position during the transportation, keep the
unit in a vertical position for approximately 24 hours before using the unit and
turning it on, to allow the oil to flow back into the compressor.
Summary of Contents for DZW-1200
Page 11: ...11...
Page 13: ...13 CIRCUIT DIAGRAM...