12. Tips and notes
• Light refraction and sunlight can cause measuring errors during
outdoor use. Perform measurements under suitable light conditions.
• When using the product outdoors, protect it from moisture and
humidity.
• The following surfaces can affect the measurement due to their
physical characteristics:
- Transparent surfaces (e.g. glass, water)
- Reflecting surfaces (e.g. glass, shiny metals)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
• Attach the hand strap to the eyelet located in the lower right area
of the housing.
13. Troubleshooting
Code
Cause
Solution
ERR01 Reflected signal too
strong
Select another measurement
surface or attach a sheet of
white paper to the surface.
ERR02 Measurement range
exceeded
Observe the correct
measurement range.
ERR03 Reflected signal too
weak
Select another measurement
surface or attach a sheet of
white paper to the surface.
ERR06 Batteries weak
Replace the batteries.