Mounting

Wall Mounting: Install the supplied mounting screws 5

apart,

and leave the heads out from the mounting surface about

^

.

Hang the NT1 on the screws and slide down to secure. If

necessary, remove the NT1 and adjust the screws to secure the

unit.
Rack Mounting: Insert the NT1U-220TC into the appropriate

slot in the rack. Any unit may be inserted or removed from an

operational rack without affecting the performance of other NT1

units. Power is supplied through the rack.

Powering Arrangements

The NT1 and terminal equipment may be powered through

several different arrangements. In a stand-alone configuration,

the optional Tone Commander Desktop Power Supply (P/N

901034) can be used to power both the NT1 and terminal

equipment. Plug the power supply barrel connector into the

Power jack on the NT1. In a rack configuration, NT1 power is

provided by the rack. In either configuration, terminal power can

be provided through the NT1 by either of the following methods:
PS2 – Direct power feed on Terminal jack pin 7 (-) and pin 8 (+),

8 watts maximum per terminal (16 watts total).

PS1 – Phantom power feed over the transmission pairs,

Terminal jack pins 3/6 (+) and pins 4/5 (-), 4 watts maximum

(total for all terminals).
Mixed power can be used if maximums are not exceeded.
Alternately, a stand-alone NT1 may be powered from a local

power source on the S/T or U interface. The power source must

be able of supplying 1.4 watts at 34-56.5 VDC to the NT1 in

addition to any other loads. Connect the power source to pin

7(-) and pin 8(+) on the Line or Terminal connectors; metallic

interconnection between connectors is provided by the NT1.

CAUTION

: Make sure only one power source is connected to

either the S/T or U interface and do not use the Desktop Power

Supply or rack power; damage to equipment may result.

Installation and Troubleshooting

Connect the network U interface from the telco to the Line jack

on the NT1 using the supplied modular cord. Connect terminals

to either Terminal jack using four pair unshielded twisted pair

(UTP) cable, Category 3 or better, with T568A or T568B wiring.
The NT1U-220TC performs a diagnostic self test at power-up or

when the reset button is pushed. All four status indicators will

light for one second during the test.
Wiring connections to the terminal equipment can be verified

before the network line is connected. Connect the terminal

equipment to one of the Terminal (S/T) jacks on the NT1 and

power-up the equipment. As soon as the terminal equipment

attempts to activate, the Line Error LED will flash. After 20

seconds, the NT1 will activate the terminal equipment and the

Terminal Error LED will also flash. Connect only one terminal

device at a time; repeat the test for each terminal device.
The network line can be verified with or without connecting

terminal equipment. Connect the network U interface to the Line

jack on the NT1. Initially, only the Power LED will light. After the

NT1 synchronizes with the network, the Terminal Error LED will

light if no terminal is connected; otherwise, the Active LED will

light. Be patient; in some instances, the network may take up to

3 minutes to synchronize with the NT1.
DC Sealing current is applied by the telco to prevent oxidized

junctions on the network line. Sealing current is usually present,

but not required

for NT1 operation. The NT1U-220TC will

display sealing current status when both the network line and at

least one terminal are connected. Lack of sealing current does

not conclusively indicate a bad line connection, since sealing

current is not always provided by the network.

Incorrect termination on the S/T (terminal) interface is a

common cause of unreliable terminal operation. Symptoms

include random data errors, intermittent or steady Terminal Error

indication, or complete terminal malfunction. Network line

synchronization is not affected. Refer to the wiring configuration

diagrams in the Termination Switch section for the appropriate

termination setting.
To fully operate with the network, the terminal equipment must

also be correctly programmed with required operating

parameters (such as SPID, directory number, etc.) that are

provided by your telco. Consult your terminal equipment

documentation for programming instructions.

Reset Button

Press the Reset button (located next to the Power indicator) to

reset the NT1 and force network and terminal

resynchronization.

CAUTION

: Pressing the Reset button during

normal operation will temporarily disrupt communication

services and will disconnect a call in progress.

Status Indicators

The operating state of the NT1U-220TC is displayed on four

status indicator LEDs.

Tone Commander Product Warranty

For a period of one year from date of dealer purchase, but not to exceed

16 months from date of manufacture, Tone Commander Systems, Inc.

(Tone Commander) warrants its products to be free from defects in

material and workmanship under conditions of normal use and service.

Tone Commander shall, at its option, repair or replace any defective

product which, in its opinion, has not been misused, damaged, or

improperly installed.
Repair or replacement under this warranty will be performed at Tone

Commander’s factory. Authorization must be obtained from Tone

Commander prior to returning a product for repair. Freight must be

prepaid for all units returned to Tone Commander. Units repaired under

warranty will be return shipped UPS Brown Label (or equivalent), freight

prepaid by Tone Commander.
Products which are older than the warranty period, but less than 7 years

old, or still manufactured by Tone Commander, may be repaired at the

factory for a flat rate charge. Repaired out-of-warranty units are

warranted for 90 days from the date of repair.
The repair or replacement of a product under this warranty represents

the entire obligation of Tone Commander; Tone Commander shall not be

liable for any special or consequential damages resulting from or caused

by any defect, failure, incapacity or malfunction of any of its products.

The foregoing express warranty is in lieu of all other warranties,

express or implied, including but not limited to any implied

warranty of merchantability, fitness, or adequacy for any purpose

or use, quality, productiveness or capacity; Tone Commander, to

the extent permitted by law, hereby disclaims all such other

warranties.

11609 49th Place West – Mukilteo, WA 98275-4255

(800) 524-0024 (425) 349-1000 Fax: (425) 349-1010

www.tonecommander.com

13-102607 Rev. G

October 1999

Reviews: