background image

The Tone Commander NT1U-220TC converts an ANSI standard

2B1Q ISDN U-interface from the telco Central Office to an S/T

interface to connect to local customer terminal equipment. Both

point-to-point and multipoint ISDN terminal equipment

configurations are supported.
The NT1U-220TC complies with

ANSI T1.601-1992 and

T1.605-1991 interface standards,

including SC1 and SC2

subchannels, and is compatible

with National-1 and National-2

ISDN standards. In addition, it

may be used as a drop-in

replacement for the AT&T

NT1U-220, and is compatible with

the Tone Commander NT1-220

Rack and the AT&T NT1M-200

rack.

Specifications

NT1U-220TC

Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 – 56.5 VDC
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625 mW typical
Physical Dimensions . . . . . . . . . . . . . . . . . . . . 6.8

H x 4.4

W x 1.1

D

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 lb.
Operating Temperature . . . . . . . . . . . . . . . . . . . 0° – 50° C (32° – 122° F)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . 5% to 95%, non-condensing

Optional Desktop Power Supply

(P/N 901034)

Power Requirements. . . . . . . . . . . . . . . . . . . . . . 120 VAC, 60 Hz, 15 W
Power Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6 A @42 VDC min.
Short Circuit Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . self-resetting
Physical Dimensions . . . . . . . . . . . . . . . . . . . . 2.2

H x 2.6

W x 3.3

D

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 lbs.

Important Safety Instructions

·

Never install telephone wiring during a lightning storm.

·

Never install telephone jacks in wet locations unless the jack

is specifically designed for wet locations.

·

Never touch uninsulated telephone wires or terminals unless

the telephone line has been disconnected at the network

interface.

·

Use caution when installing or modifying telephone wires.

·

When powering the NT1 through the Power connector, use

only the Tone Commander Desktop Power Supply (P/N

901034-01).

·

Do not mount the NT1U-220TC within 12

of a heat source.

FCC Requirements

The Tone Commander NT1U-220TC has been tested and found to

comply with the limits for a Class B digital device, pursuant to Part

15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference when the

equipment is operated in a residential environment. This equipment

generates, uses, and can radiate radio frequency energy and, if not

installed and used in accordance with the instruction manual, may

cause harmful interference to radio communications. However,

there is no guaranty that interference will not occur in a particular

installation. If this equipment does cause harmful interference to

radio or television reception, which can be determined by turning

the equipment off and on, the user is encouraged to try to correct

the interference by one or more of the following measures:

·

Where it can be done safely, re-orient the receiving television or

radio antenna.

·

To the extent possible, increase the separation between the

telephone equipment and the television, radio, or other

equipment.

·

If your telephone equipment runs on AC power, plug your product

into an AC outlet that is not on the same circuit as the one used

by your radio or television receiver.

Termination Switch

The termination switch is located on the back of the NT1. It

must be set prior to mounting the NT1. Available settings are

OFF

,

100

W

, and

50

W

.

Set the termination switch to match the premises wiring

between the NT1 and the terminals. Several typical wiring

configurations are shown below, with the appropriate

termination switch setting.
Fixed or adaptive timing selection is not required.

Connectors

Two terminal connectors are provided for convenient terminal

installation; both are parallel connected to the S/T interface.

Pins 7 and 8 of the Terminal and Line connectors (power pins)

also have metallic interconnection.

NT1U-220TC

Installation

Instructions

!

The use of Category 3 or better unshielded twisted pair

cable with T568A or T568B connector wiring is

recommended. Distances shown are maximum for

24-gauge wiring cable, and may vary for other cable types.

RACK

CO NNECTO R

TERM INAL

LINE

PO W ER

TERM INAL

1

8

1

8

1

8

3 – RCV+

6 – RC V-

4 – XM T+

5 – XM T-

7 – -48V

8 – -48V RTN

TERM INAL (S/T)

CO NNECTO RS

4 – TIP

5 – RING

7 – -48V

8 – -48V RTN

LINE (U)

CO NNECTO R

Reviews: