4. Installation, Piping and Wiring
4.1 Installation Location
(1) The pump should be close to the ground and located near the inlet tank.
(2) There should be sufficient space reserved around the pump to facilitate future
maintenance and repairs.
(3) The pump and its wiring should be placed in a relatively dry environment, protected
from possible flooding.
(4) Install in the place where the ambient temperature is not above 40°C.
(5) Fastening the pump to base plate or machine with anchor bolt.
1. Be sure to use the hanger bolt to lift the pump. Do not hang with the other
position of the pump. When hoisting, do not pass under a raised pump. A
serious injury could occur if the pump is accidentally dropped.
2. Before lifting, check the weight of the pump. Do not lift a pump which
exceeds the rated weight of the hoist. And, be sure no one standing below
the pump while lifting or transporting.
Install or store the pump in the following places with special care and consult
with TOMY ENG CORP. or authorized dealer in the near region:
a. Places where flammable gas, dust or material is used or placed.
b. Places where corrosive gas is generated.
Places where the ambient temperature is extremely higher than 40°C or
extremely lower than 0°C.
4.2 Piping
(1) TEM flange is the RF type adjustable
flange which can be oriented to
match corresponding bolt holes to
facilitate piping installation.
(2) TEM flange screw is either M16 or
5/8”. The tightening torque is 5 N-m.
(3) The allowable load of pipe on the
pump.
X
Y
Z
Z
Y
X
Model
SUCTION
Force (N)
Moment (N-m)
Fx
Fy
Fz
ΣF
Mx
My
Mz
ΣM
TEX/TEM-220/221/440/441 120
100
100
180
20
30
20
60
TEX/TEM-542/543/545
120
100
100
180
30
50
30
75
TEX/TEM-653/655
150
120
120
200
30
50
30
75