severe circumstances, clean the air filter element every 10
hours; If necessary, change the air filter element every 25
hours.
●
Maintain the generator based on whatever number comes
first: the hours of operation, or the timeframe (ex: oil change
every 3 months)
●
If you have missed the scheduled time to maintain your
engine, do it as soon as possible.
Stop the engine before servicing. Put the engine on a
level surface and remove the spark plug cap to prevent
the engine from starting.
Never run your engine in a poorly ventilated room or
other enclosed area, be sure to keep good ventilation in
the working area. The exhaust from the engine may
contain poisonous CO, and inhalation can cause shock,
unconsciousness and even death.
1. Engine Oil Change
Drain the oil while the engine is warm to assure complete
and rapid draining.
1. Remove the oil dipstick and drain plug to drain the oil.
2.Reinstall the drain plug, then tighten the plug securely.
3. Refill oil and check the oil level.
Oil capacity: 28.7 fl oz