![Tokyo Hy-Power HL-350VDX User Manual Download Page 9](http://html1.mh-extra.com/html/tokyo-hy-power/hl-350vdx/hl-350vdx_user-manual_1125174009.webp)
*Wiring Details for REMOTE TERMINAL (remote controller connection jack) are
as follows:
(Don’t connect
ACC CONNECTOR here!)
When viewed
from the outside
of the rear panel
→
Terminal No.
Noun
Connection Details
①
RX SW
This is connected to the switch of RX pre-amp.
When 13.8VDC is applied, the RX pre-amp will
be turned ON.
②
VCC
This is connected to the + wire of the power
supply cable.
This pin always supplies 13VDC.
③
HI/LO SW
When LO POWER position is selected, this pin
will supply 13VDC.
④
WARNING
When WARNING Lamp is turned ON, this pin
will supply the voltage for lighting LED.
⑤
TX
When the transmission is being made, this pin
supplies 13VDC (50mA max.).
⑥
GND
This is a grounding pin.
⑦
POWER SW This is connected to POWER SWITCH.
When 13.8VDC is applied here, POWER will
be turned ON.
⑧
NC
This pin is not connected to anywhere.
8