15
VI.Event record description
Event recording is currently an optional feature and can only be read through communications. The specific instructions are as follows:
6.1 Event Types
6.2 Event Record Format
6.3 Reading of event records
ADD
XX
Order
03
Data ADD
45
XX
Data length
Event Type
1
2
3
4
5
6
7
8
9
10
1
No.
Correspondence data
2
3
4
5
6
7
8
9
10
Power on the meter
Event Desciption
modified parameter
Clear Energy
Clear Demand
Clear Event
Clear maximum
1st alarm action
1st alarm end
2nd alarm action
2nd alarm end
1-10
Year
Month
Day
Hour
Minute
Second
Event Occurred Time
00
07
CRC
XX
XX
A total of 32 groups of events were included, both of which included event types and times. The event record uses a sequential recording
method: the first record is always the most latest event and extends back to a total of 32 records. Records older than the latest 32 records
will be discarded.
Eg, To read the latest first record, the data is as follows
:
“01 03 45 00 00 07 13 EC”
Answers are as follows
:
“01 03 0E 00 01 00 0E 00 09 00 12 00 11 00 07 00 21 0C F7”
Indicates that the event is a modified parameter. The moment of occurrence is2014-9-18 17:07:33
Including the followed 10 types
: