In case the external power source is not fitted with current limiting function,

please use FUSE (Max. 10A).

FUSE is not necessary if the power source fitted with current limiting function is used.

TRT-2416  operation manual

Thank you for purchasing our TRT-2416. Please thoroughly read this manual. This manual is a brief version of the operation manual.

Cautions

For safety purpose, following symbols are used in this manual.

!

The case that a user may receive fatal damage, electric shock, or severe burn injury

when the product is incorrectly used

The case that a user may receive minor injury or the equipment may get damage

Verify correct wiring before turning on electricity since incorrect wiring may cause an equipment failure 
or a fire. Modification of this equipment may cause malfunctioning or a fire. Do not add modification on 
this equipment. If the equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired.

!

!

Wiring – If the current would be large in the output terminal (OUT 1, OUT 2) as well as in the power 
terminal (DC24V

+-

), use wire material thick enough for such current (within the current rating).

!

- Hand over this operation manual to a person who actually operates the product. 
- Content of this manual may be subject to modification without prior notice.

- Do not reprint or duplicate this manual without permission.

Verification of the product

1

Verification of the model: Refer the model name printed in the packing 

box to the order sheet.

2) Model: TRT-2416

Environmental condition

1

Service temperature/humidity range: 

0-50 

/ 20-90 % RH 

no dew condensation

2

Storage temperature/humidity range: 

-20-70 

℃ (

no freezing or dew condensation

/5-95 % RH 

no dew condensation

(3) Installation environment :

1) No corrosive gases, dust, oil as well as less temperature changes.

2

As far away as possible from an electric noise source, and little effect from

electromagnetic field

3) A location with as few mechanical vibrations or impact as possible.
4

No direct sunlight

5

Installation category I / Pollution Degree2

!

Warning

The tightening torque for the terminal block screw is as follows:
0.4N

m

[Input Portion]

0.49 N

m

[Power source / Output Portion]

0.66 N

m

[Main body attachment portion]

If the polarity (+, 

) is specified, be careful with its wiring.

Head office: 2-4-3 Nishihashimoto, Midori-Ku, Sagamihara-Shi, Kanagawa 252-0131 Japan

TEL: +81-42-700-2100, FAX: +81-42-700-2112

Horizontal position

Vertical position

Mounting

Attachment hole dimension

*Due to risk of electric shock, do not touch the terminals while the power is running through the unit.
*Since the unit is designed to radiate heat from the bottom, do not cover this portion with insulating materials.
* We shall not be held responsible for any damages that may occur as a result of excessive usage beyond 

the ranges and specifications mentioned in this specification manual.

*Please use the unit with utmost care and safety in mind in such a way that the unit be used with some 

allowance to its rating and performance, and to limit the damage to minimum in case of trouble.

*Regardless of the place of use, the unit may bring about serious effect due to aging or trouble of the unit.  

It is therefore advised to install proper external protective circuits and perform regular maintenance.

*If this product is used with output current of 16A, only the external power source fitted with current 

limiting function may be used.

(In case the power source is not fitted with current limiting function, please make use of the 

FUSE (Max. 10A) between the power source and the unit. In this case, up to 10A can be used.)

* The parts used in the unit may change without prior notice due to procurement related consequence, 

and if the parts will not have any problem in its performance.

*

CAUTION !!   REGARDING POWER LINE SERGE)

please avoid common connection of the induced load such as relay to the power source for driving the Peltier Relay.

* When making one-on-one connection of the several Temperature Controllers to
several Peltier Relays, do not connect more than two pairs to one power source.

!

Cautions

When power source with current limiter is used as an external power source.

When using a fuse for the external power source.

Output Characteristic

Ambient Temperature - Current Characteristic

Input 

Installation gradient

Mounting

Input Point

2-points (IN 1, IN 2 , GND common)

DC 12V <ON> ,  DC 0V<OFF>

Min. Input Time
Input Resistance

Connection Method

More than 2ms (Level Input)
2.8k

Ω 

Standard

Terminal Block (M3 screw)

Input Kind

Output Point

1-point

Voltage

Output Kind

Output

Connected to Peltier Drive Output (OUT 1, OUT 2)

Output Type

ON/OFF (MOS FET Output: For Peltier Drive, with inverting function)

Output Voltage

± (DC 8 

24V) The voltage is dependent on external power voltage, 

polarity is dependent on the inverting function.

Max. Output Current

16A

 (

Refer to Table of Output Characteristic

Connection Method

Terminal Block (M4 screw

Service temperature/humidity range

Storage temperature/humidity range

0-50 

/ 20-90 % RH 

no dew condensation

-20-70 

℃ (

no freezing or dew condensation

/5-95 % RH 

no dew condensation

Base plane 0 or 90 degrees (vertically with output side in upward direction

Use M4 screw to attach the product.

Weight

100 g  or  less

External code and standard None

Isolation

Non-isolated with power circuit, non-isolated with Peltier drive circuit.

Input portion

Power portion / Output portion

*For the crimp-type terminal of Power portion / Output portion, use M4 type with

insulating sheath.

*For the crimp-type terminal of Input portion, use M3 type with insulating sheath.

Specifications

Names and Functions

External Dimension

(TRT-2416)

Below diagram shows the sample wiring when the product is connected to 
TTM-204 Temperature Controller.

IN1

,2, GND

OUT 1,

Peltier drive output

DC24V(+,-)

External Power Input

Movement of Input (1, 2) and Output (1, 2)

1 The table of real value shows the input 1, 2 to be the input voltage from 

the temperature controller.
ON (12V) OFF (0V) is shown to be the temperature controller output.

2 The table of real value shows the output 1, 2 to be the Peltier drive output polarity.

In case the <Output 

=+

Output 2 =->,  current flows from output 1 side to output 2 side.

3 Heating and cooling will change depending on the direction in which the Peltier

element is attached.

IN1

IN2

OUT1

Condition

Heating

Cooling

OFF

12V

When IN 1 is ON, the output condition <OUT 1 = +, OUT 2 = 

will be retained even if the voltage of IN 2 changes.

0V

0V

12V

0V

0V

+

-

No Output

-

+

Rating

Characteristics

monitor 

display

DC 0V

1V

5mA MAX

at ON

Output specification

MOS FET Output (for Peltier drive with polarity reversion function)

Input 1

Green LED (

φ

3mm) 1 pc. The Green LED lamp will light-up 

Display

Power supply voltage

when the input from the SSR drive output of Input 2 becomes ON (12V)

DC 12V ±1V

Input current

ON voltage

DC8 – 24V±10% (permissible range) 

Commonly used with Peltier drive (output).

Input 

Output

Red LED (

φ

3mm) 1 pc. The red LED lamp will light-up 

when the input from the SSR drive output of Input 1 becomes ON (12V)

Input 2

Wiring

No Output

OUT2

Webpage: http://www.toho-inc.co.jp
E-mail : [email protected]

TOHO ELECTRONICS INC.

Input from the temperature controller (SSR drive output)

Input Characteristic

Voltage - Current Characteristic

OFF voltage

When IN 2 is ON, the output condition <OUT 1 = 

, OUT 2 = 

+

will be retained even if the voltage of IN 1 changes.

図番:

30-7524-F     (

)

*Base plane 0 or 90 degrees (vertically with output side in upward direction

*Use M4 screw to attach the product.

 

0

2

4

6

8

10

12

14

16

18

0

10

20

30

40

50

60

M

ax

. l

oa

cu

rr

en

t(

A

)

Ambient temperature(

)

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

10

11

12

13

14

In

p

u

cu

rr

e

n

t[

m

A

]

Input voltage[V]

Ta=25

*Kindly contact us for any questions regarding the use of heat radiator.

Without heat

Heat TRH-70(

θ

f=1.52

/W)

Heat TRH-100(

θ

f=1.14

/W)

(*)

Not recommended 
wiring example

Reviews: