![Tohnichi R-CM Operating Instruction Download Page 4](http://html1.mh-extra.com/html/tohnichi/r-cm/r-cm_operating-instruction_1124787004.webp)
4
Modular Conversoin Receiver Model: R-CM
1
Outline
This R-CM applied interchangeable radio modules and by attaching a Tohnichi radio module,
it can be used as various Tohnichi wireless Pokayoke receiver. This makes it easy to update the receiver
from a standard tightening counting type error proofing torque wrench system to data transmission type
torque wrench by changing the radio module of receiver.
In addition, it is equipped with relay contact output terminals and a RS232C output. It allows to manage
the tightening count signal by an optional count checker CNA-4mk3 or manage the tightened torque
value through RS232C to PC/PLC, it is possible to establish a preventing missed tightening system with
traceability.
2
Specifications
Model
R-CM
Display
Status lamp, LCD
Receiving LED x 4
Input/Output
Relay output x 4
Reset input, LS IN input
RS232C Input/Output
Power
DC24V (18V - 36V) *1
Power consumption: Less than 5W
Case Material
Resin
Temperature of Use
0 - 50
℃
Less than 85%RH (No condensation)
Radio Frequency
Depends on a mounted radio module * 2
Communication
Distance
Depends on a mounted radio module * 2
Radio License
Depends on a mounted radio module * 3
Standard Accessories
No.1070 (DIN rail) Fixturex 2pcs
*1. To use at AC100V ~ 240V, required an optional AC adapter model BA-8R.
*2. For details, refer to operating manual of each radio module.
*3. Consult Tohnichi for status of wireless certification acquisition for each country.