Tohnichi PHL Operating Instruction Download Page 12

東京営業所

〒 143-0016 東京都大田区大森北 2-2-12
TEL.03-3762-2452  FAX.03-3761-3852
E-mail:[email protected]

北関東営業所

〒 320-0081 栃木県宇都宮市大通 2-3-7 泉ビル 7F         
TEL.028-610-0315  FAX.028-610-0316            

大阪営業所(トルクセンター大阪)

〒 531-0074 大阪府大阪市北区本庄東 2-12-1         
TEL.06-6374-2451  FAX.06-6374-2452

名古屋営業所 (トルクセンター名古屋)

〒 480-1112 愛知県長久手市砂子 720
TEL.0561-64-2451  FAX.0561-64-2452

広島営業所

〒 732-0803 広島県広島市南区南蟹屋 2-5-2           
TEL.082-284-6312  FAX.082-284-6313

九州出張所

〒 802-0001 福岡県北九州市小倉北区浅野 1-2-39
    勧和興産浅野ビル 14 号館 50 号          
TEL.093-513-8866  FAX.093-513-8867

TOHNICHI MFG.CO.,LTD.

2-12, Omori-kita, 2-Chome Ota-ku, Tokyo, JAPAN

TEL.81 3 3762 2455   FAX.81 3 3761 3852

E-mail:[email protected]

WebSite:http://tohnichi.co.jp

N.V.TOHNICHI EUROPE  S.A.

Industrieweg 27 Boortmeerbeek, B-3190 BELGIUM 

TEL.32 16 606661   FAX.32 16 606675

E-mail:[email protected]

TOHNICHI AMERICA CORP.

1303 Barclay Blvd. Buffalo Grove, IL 60089 USA

TEL.1 (847)947 8560   FAX.1 (847)947 8572

E-mail:[email protected]

WebSite:http://www.tohnichi.com

TOHNICHI SHANGHAI MFG. CO., LTD.

Rm.5 No.99 Nong1919. Du Hui Road, Minhang, 

Shanghai, P.R.China

TEL:86(021)3407-4008 FAX:86(021)3407-4135

本社 

〒143-0016 東京都大田区大森北 2-2-12            
TEL.03-3762-2451(代表)  FAX.03-3761-3852

株式会社 

東日製作所

14.01.PO

0120-1

ト ル ク

69-1

ト ー ニ チ

21

トルクのことならお気軽に、 ご相談ください。

 7.

仕様

   

  7. Specifications

PHLE2

有効長 

L

Effective length

P

全長 

L' 

Overall length

基準径  φ

The diameter for Calibration

負荷方向

精度

ACCURACY

 ±

5%

型式

MODEL

(S.I.)

トルク調整範囲

CAPACITY

最大トルク時の手力

Max Hand Power

N

寸法

DIMENSION

 

mm

質量 

WEIGHT

kg

N•m

最小~最大 

Max

 - 

Min

1 目盛

Grad

有効長

全長

L’

パイプ

外径

呼び

基準径

φd

PHLE850N2

200 ~ 850

5

547

1554

1664

26

52

450

39

8.2

PHLE1300N2

300 ~ 1300

765

1700

1831

10

Summary of Contents for PHL

Page 1: ...Graduation Main Graduation Pipe wrench Head PHLE1300N2 To the User In order to use the torque wrench properly and safely please read this instructions before operation If any questions please contact...

Page 2: ...akage failure of a torque wrench or screw Torque wrenches are designed for tightening only They are not intended for any other use including loosening Check the handle to make sure it is free of oil g...

Page 3: ...are to avoid shocks or jolts including dropping the wrench Damage or deformation may result and accuracy and durability will be reduced Do take careful note of your surroundings when handling a large...

Page 4: ...ench handle has an effective length mark which must be used to grip it in the proper place Improper grip position will reduce accuracy A click will signal that the proper amount of torque has been app...

Page 5: ...loading direction must be at a right angle to the torque wrench The tolerance is plus minus 15 degrees of horizontal or vertical deviation See fig 5 Before using or storing the wrench or whenever nece...

Page 6: ...on of extension handle Please install the extension handle in the procedure of Fig 7 a c 2 Uninstallation of extension handle as Fig 8 Press the push button and pull the extension handle Adjusting Han...

Page 7: ...e torque in reading both main and supplementary graduation Turning it clockwise will increase the torque setting and counter clockwise will reduce it 3 Tighten the locker Reposition the pin when diffi...

Page 8: ...aduation Turning it clockwise will increase the torque setting and counter clockwise will reduce it 3 Tighten the locker Reposition the pin when difficult Supplementary Graduation Red Line Torque Set...

Page 9: ...removed Fig 11 Turning the adjusting handle clockwise increases the set torque and turning counter clockwise reduces it 2 Setting torque value can be read as Fig 12 It is 420N m in Fig 12 Torque Set...

Page 10: ...opposite direction of ONLY you don t hear a click The use for tightening the left hand screw or loosening the bolt may cause a failure Tightening is complete when a click is heard or felt 13 Fig 13 Fo...

Page 11: ...diameter for Calibration ACCURACY 5 MODEL S I CAPACITY Max Hand Power N DIMENSION mm WEIGHT kg N m Max Min 1 Grad d PHL50N 10 50 0 5 170 295 316 13 38 350 25 5 1 5 PHL100N 20 100 1 270 370 472 1 6 PHL...

Page 12: ...oortmeerbeek B 3190 BELGIUM TEL 32 16 606661 FAX 32 16 606675 E mail tohnichi europe online be TOHNICHI AMERICA CORP 1303 Barclay Blvd Buffalo Grove IL 60089 USA TEL 1 847 947 8560 FAX 1 847 947 8572...