Table 2.2 Gaze Precision (Preliminary)
G
Gaazzee p
prreecciissiio
onn
TTo
ob
biiii X
X2
2--6
60
0 E
Eyyee TTrraacckkeerr C
Coom
m--
p
paacctt E
Ed
diittiioonn
T
Toob
biiii X
X2
2--6
60
0 E
Eyyee T
Trraacckkeerr W
Wiid
dee
E
Ed
diittiio
onn
B
Biinno
occuullaarr
M
Moonnooccuullaarr
B
Biinnooccuullaarr
M
Mo
onnooccuullaarr
Artificial Eye
With Stampe filter 2
1
Pending
Pending
Pending
Pending
Without filter
Pending
Pending
Pending
Pending
Human Eye
With Stampe filter 2
Pending
Pending
Pending
Pending
Without filter
0.32
0.43
0.32
0.43
1.
Stampe (Behavior Research Methods, Instruments & Computers, 1993, 25 (2), pp.137-142) describes a noise reduction filter commonly used for eye tracking data. In these measurements, the
Stampe stage 2 algorithm has been applied.
Table 2.3 Eye Tracking Specifications (Preliminary)
TToob
biiii X
X2
2--6
60
0 E
Eyyee TTrraacckkeerr C
Co
om
m--
p
paacctt E
Ed
diittiioonn
TTo
ob
biiii X
X2
2--6
60
0 E
Eyyee TTrraacckkeerr W
Wiid
dee
E
Ed
diittiioonn
S
Saam
mp
plliinng
g rraattee
60 Hz
(std. deviation approx. 0.1Hz)
60 Hz
(std. deviation approx. 0.1Hz)
TToottaall ssyysstteem
m llaatteennccyy
48
–
67 ms
48-67 ms
TTiim
mee ttoo ttrraacckkiinng
g rreecco
ovveerryy
For blinks: immediate
For blinks: immediate
H
Heeaad
d m
moovveem
meenntt
1
Freedom of head move-
ment at 70 cm (width x
height)
50 x 36 cm (20 x 14
ʺ
)
50 x 36 cm (20 x 14
ʺ
)
Operating distance
(eye tracker to subject)
45
–
90 cm (15.7
–
33.5
ʺ
)
50
–
100 cm (20
–
39
ʺ
)
R
Reeccoom
mm
meennd
deed
d ssccrreeeenn ssiizzee
up to 22
ʺ
up to 27
ʺ
D
Daattaa ssaam
mp
pllee o
ouuttp
puutt
Timestamp, eye position, gaze point,
pupil diameter, validity code
Timestamp, eye position, gaze point,
pupil diameter, validity code
1.
Freedom of head movement describes the volume in front of the tracker in which the user must have at least one of the eyes. The numbers are specified parallel/orthogonal to screen surface, as-
suming eye tracker is at 20 degree angle to screen.
Table 2.4 Eye Tracking Units (Preliminary)
T
Toob
biiii X
X2
2--6
60
0 E
Eyyee T
Trraacckkeerr C
Coom
mp
paacctt E
Ed
diittiioonn
TToob
biiii X
X2
2--6
60
0 E
Eyyee TTrraacckkeerr W
Wiid
dee E
Ed
diittiioonn
E
Eyyee ttrraacckkeerr p
prro
occeessssiinng
g
uunniitt
Tobii X2-60 Eye Tracker external processing
unit
Tobii X2-60 Eye Tracker external processing
unit
C
Coonnnneeccttoorrss
USB 2.0
USB 2.0
W
Weeiig
ghhtt
200 g (7.1 oz)
250 g (8.8 oz)
S
Siizzee
184 x 28 x 23 mm (7.2 x 1.1 x 0.9
ʺ
)
400 x 28 x 23 mm (15.7 x 1.1 x 0.9
ʺ
)
M
Moouunnttiinng
g ssoolluuttiio
onnss
Adhesive Mounting brackets for monitors, lap-
tops and tablets. Desk Stand Accessory pack-
age for Tripod and desks
Adhesive Mounting brackets for monitors,
laptops and tablets. Desk Stand Accessory
package for Tripod and desks
Table 2.5 Tobii X2-60 Eye Tracker external processing unit
C
Coonnnneeccttoorrss
USB 2.0, LAN and power connector
S
Siizzee
116.6 x 112 x 39 mm (4.6 x 4.4 x 1.55
’’
)
W
Weeiig
ghhtt
500 g (17.6 oz)
6
Product Description v.1.0 - en-US