SPECIFICATIONS: Gas Griddle

MODEL: TMGM24, TMGM36, TMGM48, TMGT24, TMGT36, TMGT48

IL1876

1 13/16

 [4.6]

"Width"

"B"

5 1/2

 [14.0]

4 - 5.375

15 17/32

 [39.4]

27 13/16

 [70.6]

29”

 [73.7]

5 5/16

 [13.5]

19

 [48.3]

5 29/32

 [15.0]

B = Width - 3.25”

Model

Height x Width x Depth

Grid Area

Controls

NAT / LP 

Weight

Installed

Shipped

TMGM24

15.5” x 24” x 29”

498 sq. in

2 Manual

NAT: 40,000 BTU/HR

147.4 lbs

157.4 lbs

39.4cm x 61cm x 73.7cm

3213 sq. cm

66.8 kg

71.4 kg

TMGM36

15.5” x 36” x 29”

747 sq. in

3 Manual

NAT: 60,000 BTU/HR

220.5 lbs

235.5 lbs

39.4cm x 91.4cm x 73.7cm

4820 sq. cm

100 kg

106.7 kg

TMGM48

15.5” x 48” x 29”

996 sq. in

4 Manual

NAT: 80,000 BTU/HR

294.7 lbs

314.7 lbs

39.4cm x 121.9cm x 73.7cm

6426 sq. cm

128.67 kg

142.7 kg

TMGT24

15.5” x 24” x 29”

498 sq. in

2 T-Stat

NAT: 40,000 BTU/HR

147.4 lbs

157.4 lbs

39.4cm x 61cm x 73.7cm

3213 sq. cm

66.8 kg

71.4 kg

TMGT36

15.5” x 36” x 29”

747 sq. in

3 T-Stat

NAT: 60,000 BTU/HR

220.5 lbs

235.5 lbs

39.4cm x 91.4cm x 73.7cm

4820 sq. cm

100 kg

106.7 kg

TMGT48

15.5” x 48” x 29”

996 sq. in

4 T-Stat

NAT: 80,000 BTU/HR

294.7 lbs

314.7 lbs

39.4cm x 121.9cm x 73.7cm

6426 sq. cm

128.67 kg

142.7 kg

Summary of Contents for TMGM24

Page 1: ...Models TMGM24 TMGM36 TMGM48 T Stat Models TMGT24 TMGT36 TMGT48 Installation and Operation Instructions 2M Z12966 Rev Oct 1 2009 TMGM36 is a registerd trademark of Toastmaster A Middleby Company All ri...

Page 2: ...s in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIR...

Page 3: ...7 sq in 3 Manual NAT 60 000 BTU HR 220 5 lbs 235 5 lbs 39 4cm x 91 4cm x 73 7cm 4820 sq cm 100 kg 106 7 kg TMGM48 15 5 x 48 x 29 996 sq in 4 Manual NAT 80 000 BTU HR 294 7 lbs 314 7 lbs 39 4cm x 121 9...

Page 4: ...sure testing of that system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manua...

Page 5: ...ural gas MANUAL SHUT OFF VALVE A manual shut off valve should be installed upstream from the union and within 6 feet 1 829m of this appliance PROPANE GAS This griddle is equipped with fixed orifice ho...

Page 6: ...229 9 C 3 Close the air shutter on the front of the burner to give a soft blue flame having luminous tips and open to a point where the yellow tips disappear and a hard blue flame is obtained Repeat...

Page 7: ...hich is extremely difficult to remove To prevent this condition the following suggestions for cleanliness should be followed 1 After each use scrape the griddle with a scraper or flexible spatula to r...

Reviews: