background image

3

1. SAFETY PRECAUTIONS

•  Before installation or use, be sure to carefully read all the instructions in this section for correct and safe 

operation.

•  Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or 

cautions regarding safety.

•  After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property 

damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and 

understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

Indicates a potentially hazardous situation which, if mishandled, could 

result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage.

wARNING
CAUTION

  

when Installing the Unit

•  Do not expose the unit to rain or an environment 

where it may be splashed by water or other liquids, 

as doing so may result in fire or electric shock. 

•  Since  the  unit  is  designed  for  indoor  use,  do  not 

install it outdoors. If installed outdoors, the aging of 

parts causes the unit to fall off, resulting in personal 

injury. Also, when it gets wet with rain, there is a 

danger of electric shock. 

•  (Applicable  to  VX-3004F,  VX-3008F,  VX-3016F, 

VX-015DA, VX-030DA, VX-050DA, rm-200Sf, 

rm-300X, and VX-3000DS only)

  Use  the  unit  only  with  the  voltage  specified  on 

the unit. using a voltage higher than that which is 

specified may result in fire or electric shock.

•  (Applicable to VX-3000DS only)

  Do not cut, kink, otherwise damage nor modify 

the power supply cord. In addition, avoid using the 

power cord in close proximity to heaters, and never 

place heavy objects -- including the unit itself -- on 

the  power  cord,  as  doing  so  may  result  in  fire  or 

electric shock. 

•  (Applicable to RM-200SF, RM-300X, RM-320F, and 

rm-210f only)

  Avoid installing or mounting the unit in unstable 

locations, such as on a rickety table or a slanted 

surface. Doing so may result in the unit falling 

down and causing personal injury and/or property 

damage. 

•  (Applicable to RM-200SF, RM-300X, RM-320F, and 

rm-210f only)

  Install the unit only in a location that can structurally 

support the weight of the unit and the mounting 

bracket. Doing otherwise may result in the unit 

falling  down  and  causing  personal  injury  and/or 

property damage.

when the Unit is in Use 

•  Should  the  following  irregularity  be  found  during 

use, immediately switch off the power, disconnect 

the power supply plug from the Ac outlet and 

contact your nearest TOA dealer. make no further 

attempt to operate the unit in this condition as this 

may cause fire or electric shock. 

· If you detect smoke or a strange smell coming 

from the unit

·  If water or any metallic object gets into the unit 

·  If the unit falls, or the unit case breaks 

·  (Applicable to VX-3000DS only)

  If the power supply cord is damaged (exposure of 

the core, disconnection, etc.)

·  If it is malfunctioning (no tone sounds)

•  To prevent a fire or electric shock, never open nor 

remove the unit case as there are high voltage 

components inside the unit. 

  (Applicable  to  VX-3004F,  VX-3008F,  VX-3016F, 

rm-200Sf, rm-300X, and VX-3000DS only)

  Refer all servicing to qualified service personnel.

•  Do  not  place  cups,  bowls,  or  other  containers  of 

liquid or metallic objects on top of the unit. If they 

accidentally spill into the unit, this may cause a fire 

or electric shock. 

wARNING

Summary of Contents for VX-3000 SERIES

Page 1: ...ings Options Manual silencing of voice alarm condition manual reset of voice alarm condition voice alarm condition output indication of a fault related to voice alarm zones voice alarm manual control...

Page 2: ...FETY PRECAUTIONS 3 2 Parts Included with The Package 5 3 Composition of The VX 3000 Instruction Manual 5 4 General Description 5 5 SYSTEM FEATURES 6 6 SYSTEM EXAMPLE 6 7 Affixing Declaration of Compli...

Page 3: ...S only Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in close proximity to heaters and never place heavy objects including the unit itself on...

Page 4: ...ting the power supply cord Reversed polarity connections will cause damage to the unit Applicable to VX 3004F VX 3008F VX 3016F and VX 3000DS only System units except remote microphones are designed e...

Page 5: ...ed into 4 parts Please read the proper manual for your purpose For unit installation For broadcast management and setup For broadcasting operation USER S MANUAL PLEASE READ THIS MANUAL FIRST Operating...

Page 6: ...em Decentralized configuration is possible via network VX 3000 system is constructed up to 128 AB zones or 512 zones as system Speaker Selector function is implemented then VX 3000 system is able to c...

Page 7: ...o the front panel of the equipment e g at the upper right side as shown below Rack EN 54 16 EN 54 16 Sticker supplied with the VX 3000F Affix only the upper part of the sticker to the equipment rack P...

Page 8: ...i Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany URL http www toa jp 133 21 00332 01 Warning This equipment is compliant with Cl...

Reviews: