22
7. CONFERENCE UNIT CONNECTION
When connecting the Conference units to the Central unit, the Expansion unit and the Bridge unit must be
installed between them.
Central unit TS-910
Expansion unit TS-918
Bridge unit
TS-919B1/919B4
Conference unit
TS-911/912/811/812
1
TS-919B1
EXPANSION
BRIDGE
BRIDGE UNIT
Coaxial cable
LAN cable (CAT-5)
Central unit TS-910 (Rear)
Expansion unit TS-918
Coaxial cable
LAN cable (CAT-5)
Central unit TS-910
Expansion unit TS-918
Expansion unit TS-918
Distributor YW-1022
(2 branches)
Coaxial cable
7.1. Central Unit and Expansion Unit Connection
Use a coaxial cable to connect the Expansion unit to the Central unit’s Expansion unit input/output terminal.
One Expansion unit can be connected per Expansion unit input/output terminal.
When connecting 2 – 4 Expansion units to a single Expansion unit input/output terminal, follow the instructions
below.
7.1.1. Connecting 2 Expansion units
Make connections as follows using the YW-1022 Distributor (2-branch distribution).