Toa TS-910 Series Instruction Manual Download Page 1

INSTRUCTION MANUAL

CONFERENCE SYSTEM

TS-910 SERIES

POWER

TALK

PRIORI

TY

POWER

TALK

Central unit

Expansion unit

Bridge unit 

(1-Conference unit 

 connection type)

Bridge unit 

(4-Conference unit 

 connection type)

Delegate unit

Chairman unit

Thank you for purchasing TOA's Conference System. 

Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

Summary of Contents for TS-910 Series

Page 1: ...l unit Expansion unit Bridge unit 1 Conference unit connection type Bridge unit 4 Conference unit connection type Delegate unit Chairman unit Thank you for purchasing TOA s Conference System Please ca...

Page 2: ...ence Unit Connections 24 7 3 Wiring 27 8 USING WIRED MICROPHONES AND SOUND SOURCE EQUIPMENT 28 8 1 Wired microphone use 28 8 2 Sound source equipment use 29 9 RECORDING EQUIPMENT CONNECTION 29 10 CONF...

Page 3: ...ONS 46 19 1 Central Unit TS 910 46 19 2 Chairman Unit TS 911 Delegate Unit TS 912 47 19 3 Chairman Unit TS 811 Delegate Unit TS 812 48 19 4 Microphone standard TS 903 Microphone long TS 904 48 19 5 Ex...

Page 4: ...falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never open nor remo...

Page 5: ...to pull If dust accumulates on the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely Switch off the power and u...

Page 6: ...irements wired microphones music playing equipment and other devices can be freely combined and used within the system Recording equipment can be easily connected to the Central unit making it ideal f...

Page 7: ...R TAL K PRI OR ITY PO WE R TAL K BRIDGE UNIT EXPANSION TS 919B4 BRIDGE 1 2 3 4 Delegate unit TS 912 812 No 1 No 4 Chairman unit TS 911 811 Bridge unit TS 919B4 Central unit TS 910 Expansion unit TS 9...

Page 8: ...ected to the External Control terminal 30 or 32 performs priority operation In this event three function setting switches 16 17 and 18 cannot be used 7 AUX 1 input volume control Adjusts the input sig...

Page 9: ...witch Determines the priority mode when the Talk key of the Conference unit is pressed Refer to p 35 A First in first out priority B Last in first out priority C Priority fixed for the first unit and...

Page 10: ...erial port of a PC operation panel or other external control equipment 31 External control terminal selection switch Used to select either RS 232C 30 or USB 32 external control terminals 32 External c...

Page 11: ...from the DC inlet 42 Short circuit indicator Lights when the Expansion unit or its connected cable is shorted 43 Expansion unit I O terminals Connect the Expansion unit or Distributor to these termina...

Page 12: ...d both the Microphone In Use indicator 3 and the Speech indicator 5 light and the microphone turns on Pressing this key again turns off both indicators and the microphone 7 Priority speech key Gives s...

Page 13: ...when the Priority Speech key is pressed Set this switch to OFF when sound output is desired and to ON when no sound is desired Note This switch is factory preset to the OFF position 11 Voting activati...

Page 14: ...efer to the table below Model Output signal TS 911 Base language or Translation language Note Switchable by the Monitor selector switch 16 TS 811 Base language Note A headphone jack is located on both...

Page 15: ...15 18 Rear 18 Communication cable connection terminal Connects to the TS 919B4 or TS 919B1 Bridge unit with a CAT 5 LAN cable...

Page 16: ...Standard or TS 904 Long dedicated microphone 3 Microphone in use indicator Lights when the microphone is turned on for speech 4 Voting keys TS 912 only Use these keys to start end and cast voting The...

Page 17: ...the hundreds place to 0 and to ON to set it to 1 Note This number is factory preset to 000 9 Monitor volume control Adjusts the output volume of the monitor speaker and right side headphone output 10...

Page 18: ...ide Rear 13 13 Communication cable connection terminal Connects to the TS 919B4 or TS 919B1 Bridge unit with a CAT 5 LAN cable 12 Headphone volume control Adjusts the output volume of the left side he...

Page 19: ...l equipment may reduce the hum noise Note This terminal is not for protective earth 4 Cable clip Run the AC adapter cable through this clip to prevent its plug from being removed from the DC inlet 5 D...

Page 20: ...de Connects to the TS 918 Expansion unit or TS 919B4 or TS 919B1 Bridge unit 3 Conference unit connection terminals Connect to the Conference units 4 Communication cable connection terminal Bridge uni...

Page 21: ...ing unit Speaker Amplifier Expansion unit TS 918 Bridge unit 1 Conference unit connection type Bridge unit 4 Conference unit connection type I F Distributor YW 1024 or YW 1022 Central unit TS 910 I F...

Page 22: ...le LAN cable CAT 5 Central unit TS 910 Expansion unit TS 918 Expansion unit TS 918 Distributor YW 1022 2 branches Coaxial cable 7 1 Central Unit and Expansion Unit Connection Use a coaxial cable to co...

Page 23: ...TS 910 Distributor YW 1022 2 branches Distributor YW 1022 2 branches Distributor YW 1022 2 branches Coaxial cable Expansion unit TS 918 Expansion unit TS 918 Note Only one Distributor at a time can be...

Page 24: ...on unit Two types of Bridge units are available the 1 Conference unit connection type and the 4 Conference unit connection type The number of connection terminals for each type is as follows Number of...

Page 25: ...as shown below depending on the combination of two types of Bridge units Combination of Bridge units Number of connectable units TS 919B4 only One or two TS 919B4s TS 919B4 and TS 919B1 mixed One TS 9...

Page 26: ...ANSION BRIDGE BRIDGE UNIT 1 TS 919B1 EXPANSION BRIDGE BRIDGE UNIT Coaxial cable LAN cable CAT 5 BRIDGE UNIT EXPANSION TS 919B4 BRIDGE 1 2 3 4 BRIDGE UNIT EXPANSION TS 919B4 BRIDGE 1 2 3 4 BRIDGE UNIT...

Page 27: ...RG 11 U Between the Expansion unit and the Conference units LAN cable UseLANcablesthatarecompatiblewithUTPCategory 5 straight cable or that can support transmission speeds exceeding that of Category...

Page 28: ...l Rear panel MIC 1 or MIC 2 input terminal When using no Distributor Maximum cable distance 200 m Distance between the Central unit and Expansion unit 100 m max Distance between the Expansion unit and...

Page 29: ...AUX 1 AUX 2 or AUX 3 input terminal Line output 9 RECORDING EQUIPMENT CONNECTION Connect the recorder s recording input terminal to the Central unit s recording output terminal If the recorder has it...

Page 30: ...at the Central unit Speaking into the microphone adjust the Central unit s Speech volume control to an appropriate level Step 5 Initiate speech from the microphones of all Conference units and confirm...

Page 31: ...screws removed in Step 1 Step 3 Mount the Central unit equipped with the mounting brackets in the rack Use the rack mounting screws and fiber washers supplied with the rack mounting bracket Fiber wash...

Page 32: ...Rack mounting bracket 2 Fiber washer for M5 2 2 Component parts and accessories of MB 15B J Coupler 2 5 x 12 rack mounting screw 2 M3 x 12 machine screw 2 3 x 14 tapping screw 2 Use the optional MB 1...

Page 33: ...its the number of installed Delegate units and the total number of installed Chairman and Delegate units respectively Step 2 Press the Voting Start End button for 1 second or more after confirming the...

Page 34: ...Recording output Line output Base language Translation language Translation language Base language LINE REC OUT Note MIX CUT MIX CUT MIX CUT Microphone Mix Cut switch for translation language Microph...

Page 35: ...eech is initiated on a first come first served basis When the maximum number of speakers is reached subsequent speech requests cannot be accepted even if the Talk key is pressed Example showing the nu...

Page 36: ...showing the number of simultaneous speakers set to 2 14 3 Mic Off Function This function automatically turns off the microphone if the user neglects to turn it off following speech completion This fun...

Page 37: ...ge channel except during priority speech from the Chairman unit regardless of the switch setting Inputs to the AUX 3 terminal are always relayed to both the base and translation language channels rega...

Page 38: ...nit cannot be used for speech if the indicators do not light Step 2 Speak into the microphone Step 3 Press the Talk key again after speech completion The indicators go out and sound can be output from...

Page 39: ...SET Resets all units currently being used for speech Factory preset position When an interrupted party wishes to continue to speak the Speech key must again be pressed Note The Chairman unit that init...

Page 40: ...o out and sound can be output from the monitor speaker Note After the priority speech is completed the other interrupted unit resumes operation as predetermined by the setting of the Interrupted Prior...

Page 41: ...taled number of votes polled with the press of the vote keys is instantly displayed on the Central unit s voting result display Tips To cancel voting Press the lit key initially pressed for voting aga...

Page 42: ...use the FBS switch and FBS control knob When using the built in FBS function perform it in automatic operation mode first Note If acoustic feedback cannot be suppressed with the built in FBS function...

Page 43: ...g so may cause damage to the knob Step 3 If acoustic feedback does not stop even when the knob reaches the immovable position seek the feedback point by gradually rotating the FBS control knob clockwi...

Page 44: ...ansion unit I O terminals Cannot operate the Talk key Unit address numbers outside range of 001 192 Set the unit address number within the range of 001 192 Refer to the CONFERENCE UNIT INSTALLATION AN...

Page 45: ...Symptom Cause and Points to Check Remedy Cannot switch ON the power Power cord or DC plug not connected Correctly connect the power cord and DC plug supplied with the Central unit Refer to the SYSTEM...

Page 46: ...20 dB 10 k unbalanced RCA pin jack Number of Connectable Chairman Delegate Units 192 units Expansion unit I O Terminal BNC jack Number of Connectable Expansion Units 4 units Up to 8 units connectable...

Page 47: ...l XLR 4 31 type dedicated for connecting the optional TS 903 or TS 904 Output Monitor speaker 8 0 2 W Headphones 3 5 mm mini jack 3P monaural x 2 Connection Terminal RJ45 connector LED Indicator Speec...

Page 48: ...18 Expansion unit Current Consumption Max 60 mA Modulation Method Frequency modulation Carrier Frequency Transmission Audio channel 1 7 35 MHz Audio channel 2 8 10 MHz Audio channel 3 8 55 MHz Audio c...

Page 49: ...m or 6 56 ft 1 BNC plug to BNC plug cord 50 cm or 1 64 ft 1 Not supplied with the TS 918 KR For the usable power supply cord and AC adapter consult your nearest TOA dealer 19 6 Bridge Unit TS 919B1 TS...

Page 50: ...n gray Dimensions 75 w x 122 h x 34 d mm 2 95 x 4 8 x 1 34 Weight 105 g 0 23 lb 120 g 0 26 lb Note The design and specifications are subject to change without notice for improvement Accessories Wood s...

Page 51: ...plate nickel plating Weight 120 g 0 26 lb Set Composition Mounting bracket 2 Coupler 2 Note The design and specifications are subject to change without notice for improvement Accessories Rack mounting...

Page 52: ...for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany URL https www...

Reviews: