32
Step 1. Use a screwdriver to set the Unit address number setting switch
located on the unit’s bottom side.
Set a numeral for the ones place and tens place.
Leave the switch for the hundreds place set to off whenever
using the unit.
Set the unit address number (001 – 064), taking care to ensure
that the same number is not duplicated in the system.
If the number [000] is assigned to a unit, the user of that unit
cannot speak. However, the unit can be used for monitoring.
Note
This number is factory-preset to [000].
Step 2. Mount the microphone to the Conference unit.
9. RECORDING EQUIPMENT CONNECTION
Connect the recorder's recording input terminal to the Central unit's recording output terminal. If the recorder
has its recording level control, adjust it to an appropriate recording level.
Tip: For operation of the recorder, refer to the instruction manual included with the recorder.
Tip
Connection when a RCA plug cable is used.
Central unit TS-820RC/820
(Rear panel)
Recording output (REC OUT, monaural)
Recorder
10. CONFERENCE UNIT INSTALLATION AND SETTINGS
Conference unit
Microphone (standard) TS-923
or
Microphone (long) TS-924
The figure shows the TS-821.
The figure shows the TS-821.
Conference unit
(bottom side)
(Inside of the cover)
Tens digit
Ones digit
Hundreds digit