Toa RM-200M Manual Download Page 8

GENERAL PURPOSE BROADCAST

EXPANSION FUNCTIONS

A Maximum System Employing

a Single Master Amplifier

4

-5-

1

RM-200M

RM-210 RM-210 RM-210 RM-210

VM-2120/2240

AC Adapter

AC Adapter

AC Adapter

VM-2000

EV-200

Master

Sub 1

Sub 2

Sub 3

Sub 4

Sub 5

Sub 6

Sub 7

Sub 8

NOTE: To perform surveillance of all connected equipment including 

the sub-amplifiers, an SV-200M unit should be mounted in each 
amplifier. The arrangement of the Zone keys is fixed and cannot 
be changed.  Message keys are always located next to the 
Zone keys of the last Sub-VM amplifier.

NOTE: DC 17V 200mA or larger AC adaptor is required when using a set 

of four RM-210s with an RM-200M.  AD-4800 can only supply 
power enough with a set of three RM-210s.

Zone:
1 -10

Zone:
11- 20

Zone:
21 - 30

Zone:
31 - 40

Zone:
41 - 45
Massage:
1 - 5

In the VM amplifier system, the VM-2120 or the VM-2240 can be expanded as a sub-amplifier to increase 
the number of broadcast zones. Even in this case, the number of input channels and the EV-200's functions 
remain unchanged. 

A maximum system employing a single master amplifier.

Sub-amplifier: 8 units
Number of zones: 45 zones
Remote control unit (RM-200M): 4 units

If the number of zones is increased, the number of zone selection switches will become insufficient. To permit 
individual broadcasts to such added zones, connect an Expansion unit to each remote control unit to increase the 
number of zone selection switches. Up to 4 Expansion units (RM-210) can be added to each remote control unit. 

Summary of Contents for RM-200M

Page 1: ...label Name label Power indicator Failure indicator Emergency indicator Emergency broadcast switch Groups 1 2 indicator Groups 1 2 broadcast key All zone indicator All zone broadcast key Zone selector key Zone indicator Zone Message selector key Zone Message indicator Busy indicator In use indicator Talk key DC power input jack Link connector Microphone volume control External microphone input jack...

Page 2: ...nects to the VM 3360VA or VM 3240VA for the purpose of making general broadcast announcements It communicates with the VM 3360VA or VM 3240VA through its RS 485 interface Zone selection or automatic announcement start can be assigned to the function key using the dedicated software No emergency broadcasts can be made with this microphone ...

Page 3: ...r green Lights when the Talk key 7 is pressed 9 External Microphone In Use Indicator orange green Flashes when a paging call is made from the external remote microphone Orange Indicates the mode that disables broadcasts from the unit Green Indicates the mode that allows the unit to interrupt broadcasts from external equipment 10 Not used 11 Microphone Used for making announcements 12 DIP Switch Us...

Page 4: ... Indicators green Indicator s function assigned to each indicator is determined by software settings Broadcast Zone Indicators Light when their corresponding zones are selected Automatic general broadcast Announcement Start Indicators Light when an automatic announcement is started 4 Broadcast Zone Selector Keys Automatic Announcement Start Keys Key function assigned to each key is determined by s...

Page 5: ... be assigned to the connected Remote Microphones depending on application Connection Connect each Remote Microphone in series using the Category 5 STP cable and RJ 45 connectors VM 2000 Connection to the Remote Microphone Pattern 2 Install a terminal panel between the VM amplifier and the Remote Microphone to sort wiring from each remote control unit The terminal panel also contributes to more ade...

Page 6: ...ter VM amplifier Sub VM amplifier a b c d e LINK connector RJ45 Link cable PRE OUT jack POWER AMP IN jack Audio cable Using the specified cable connect between the VM amplifier s and Remote Microphone s via their LINK connectors They can be connected in any order Two connection examples are shown TIA EIA 568A standard Category 5 Shielded Twisted Pair cable straight type Abbreviated to Cat 5 STP ca...

Page 7: ...lifiers Disconnect power supply pins 1 2 7 and 8 from the link cable and connect the two VM amplifier units Connection RM 200M VM Amplifier AC Adapter AC Adapter IT 450 EBA SJP1402 SJP1403 SJP1401 DC Power Supply Master VM Amp EBA SJP1402 SJP1403 SJP1401 DC Power Supply Sub VM Amp RM RM 1 2 3 4 5 6 7 8 Powered by VM amplifier Pin No Colour Pair Assignment 1 orange white Power 24V 2 orange Power GN...

Page 8: ...th an RM 200M AD 4800 can only supply power enough with a set of three RM 210s Zone 1 10 Zone 11 20 Zone 21 30 Zone 31 40 Zone 41 45 Massage 1 5 In the VM amplifier system the VM 2120 or the VM 2240 can be expanded as a sub amplifier to increase the number of broadcast zones Even in this case the number of input channels and the EV 200 s functions remain unchanged A maximum system employing a sing...

Page 9: ...icrophone excluded 750 kg Power Source Current Consumption Audio Output Frequency Response Distortion S N Ratio Microphone Function Key Volume Control Connection and Cable Connector Finish Dimensions Weight Link cable 3 m 1 1 Use the AC adapter AD 246 or equivalent 2 0 dB 1 V Note The design and specifications are subject to change without notice for improvement Accessories 16 8 RM 210 Remote Micr...