5.3. Speaker and Attenuator Connection

[4-Wire System Wiring]

R

N

SP

Attenuator 

Speaker

(+)

DC Power supply

(–)

Attenuator 

Speaker

(–)

Relay
control

(+)

N

SP

Note

The attenuator is assumed to be bypassed when
the power is supplied to the attenuator relay control.

Be sure to replace the terminal cover after completing speaker cable
connection. Failure to do so may cause electric shock because up to
100 V is applied to the speaker terminal.

WARNING

5.3.1. Speaker connection

Connect speakers to either 100 V (27.8 

Ω

) or 50 V (6.9 

Ω

) terminal. 

Never use both terminals simultaneously.

5.3.2. Attenuator Connection

The PA-3640VB has a built-in relay activated by the Priority control input. The relay provides NC (normally
closed) and NO (normally open) contacts at the Priority-activated control output terminal on the rear panel. For
an emergency broadcast state when the Priority control is activated, this terminal allows 2 ways of
connections depending on the type of attenuator as shown below.

Note

In both connection methods, be sure to use the "100 V" terminal for speaker/attenuator connection. 
Never use 50 V terminal.

[3-Wire System Wiring]

Summary of Contents for PA-3640VB

Page 1: ...1 AC Power Supply 6 5 2 24 V DC Power Supply 6 5 3 Speaker and Attenuator Connection 7 6 MUTE LEVEL ADJUSTMENT For qualified service personnel only 8 7 SPECIFICATIONS 8 Accessories 8 Optional product...

Page 2: ...spill into the unit this may cause a fire or electric shock Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or e...

Page 3: ...so may cause a fire or personal injury Install the equipment rack on a stable hard floor Fix it with anchor bolts or take other arrangements to prevent it from falling down When connecting the unit s...

Page 4: ...es The unit can operate on either 220 V AC or 24 V DC The rear panel includes provision for mounting an optional YA 1000A Fault Detection Circuit Module that functions to detect power amplifier failur...

Page 5: ...ut when the Priority control is activated The Priority output terminal can be connected to the next power amplifier s Priority input terminal feeding the same Priority input sources to the amplifier 1...

Page 6: ...space should be provided upper and lower side of the units for ventilation The Perforated Panel is recommended in place of space 5 CONNECTIONS 5 1 AC Power Supply The PA 3640VB is a permanent connecte...

Page 7: ...ion Connect speakers to either 100 V 27 8 or 50 V 6 9 terminal Never use both terminals simultaneously 5 3 2 Attenuator Connection The PA 3640VB has a built in relay activated by the Priority control...

Page 8: ...JUSTMENT For qualified service personnel only When the Priority control input is activated the Priority input mutes the Program input by a preset level which can be adjusted with the Mute level contro...

Reviews: