Toa NX-100 Brochure & Specs Download Page 4

Specifications are subject to change without notice.
Printed in Japan (0408) 833-52-293-7C  u

TOA Corporation

www.toa.jp

NX-100S

NX-100

AC adapter AD-246 (optional ) 

24V DC (removable terminal block 

or the equivalent

(3 pins)) or
AC adapter AD-246 (optional )
 or the equivalent

7W (when AD-246 (optional) is used)

200mA (DC operation)

1 channel (transformer-isolated), 

1 channel (transformer-isolated), 

–58dB* to 0dB*,

–58dB* to 0dB*,

balanced (MIC/LINE changeable, 

balanced (MIC/LINE changeable, 

volume adjustable with volume control), 

volume adjustable with volume control), 

2k

, removable terminal block (3 pins)

2k

, removable terminal block (3 pins)

phantom power supply
(24V, can be set with the switch)

1 channel (transformer-isolated), balanced, 600

removable terminal block (3 pins)

50 – 14,000Hz (when sampling frequency is 32kHz)

Under 0.3% (1kHz, when sampling frequency 32kHz)

8 channels, no-voltage make contact input, open voltage: 12V DC,
short-circuit current: 10mA, removable terminal block (9 pins)

8 channels, open collector output (polarised), withstand voltage: 30V DC,
control current: 50mA max., removable terminal block (9 pins)

10BASE-T/100BASE-TX, Auto-Negotiation

TCP, UDP, ARP, ICMP, HTTP, RTP, IGMP

TCP/IP, UDP, HTTP, RTP

Unicast (up to 4 simultaneous transmissions),
Multicast (up to 64 simultaneous transmissions)

0

°

C to +40

°

C

0

°

C to +50

°

C (0

°

C to +40

°

C when

AC adapter is in use) 

Under 90% RH (no dew condensation should be produced)

Steel plate, black, 30% gloss

210 (W) 

×

 46 (H) 

×

 188 (D)mm

1.2kg

CD (PC Installation & Operation

CD (PC Installation & Operation  

software programe,

software programes, 

Instruction manuals) 

×

 1,

Instruction manuals) 

×

 1,

Audio I/O removable terminal

Power supply removable terminal 

plug (3 pins) 

×

 2, 

plug (3 pins) 

×

 1, 

Ferrite clamp 

×

 1,

Audio I/O removable terminal 

Control I/O removable terminal 

plug (3 pins) 

×

 2,

plug (9 pins) 

×

 2,

Control I/O removable terminal 

Bracket mounting screw 

×

 8

plug (9 pins) 

×

 2, 

RS-232C connector cover 

×

 1,

Bracket mounting screw 

×

 8

Rack mounting bracket: MB-15B-BK (for one NX-100/NX-100S unit)

MB-15B-J (for two NX-100/NX-100S units)

AC adapter: AD-246

Note: When you need the AC adapter, be sure to consult your TOA dealer.

Model No.

Power Source

Current Consumption

Audio Input

Audio Output

Frequency Response

Distortion

Control Input

Control Output

Network I/F

Network Protocol

Audio packet 
Transmission System

Operating Temperature

Operating Humidity

Finish

Dimensions

Weight

Accessory

Option

SPECIFICATIONS

* 0dB = 1V

APPEARANCE AND DIMENSIONAL DIAGRAM

Guidelines on Line Band, Sound Quality and Delay Time

NOTES:

Note 1: Voice packet size

  Voice packet size other than for “Line band of 1.5 Mbps or 

   higher” is for data of 1024 bytes.

    Voice packet size for “Line band of 1.5 Mbps or higher” is for 

   data of 256 bytes (PCM)/32 bytes (Sub-Band ADPCM) data.

Note 2: Voice Packet Loss Recovery

Voice Packet Loss Recovery is a processing method when 
a voice packet cannot be received due to communication 
interference.

    

Silence: Method of processing lost sectors as silence.

    

Redundancy: Method of accurately outputting continuous 
   losses of up to 8 packets.

    

Resend: Method of accurately outputting continuous 
   losses of up to 15 seconds.

Note 3: Required band

Required band represents the frequency band required for 
voice transmission. When it is necessary to transmit serial 
data, a transmission band is separately required.

 128 kbps

(Dedicated

line, etc.) 

64 kbps

(ISDN, etc.) 

50 - 3.4 kHz

8 kHz

(1) For LAN and dedicated lines

Over

1.5 Mbps

 PCM

 50 - 14 kHz

32 kHz

50 - 14 kHz

32 kHz

50 - 7 kHz

1 6 kHz

Line Band

Voice

Compression

Audio Band

Sampling

Voice Packet 

Loss

Recovery

Delay

Time

(sec)

Band
Used

(kbps)

Over

512 kbps

(ADSL, etc.) 

64 kbps

(ISDN, etc.)

Silence              2.6               34

Redundancy         15                51

50 - 3.4 kHz

8 kHz

 128 kbps

(Dedicated

    line, etc.)

50 - 7 kHz

16 kHz             Silence             1.3               68

50 - 3.4 kHz

 8 kHz       Retransmission        30                92

Retransmission       30              369

Silence             0.6             136

(2) For the Internet

50 - 14 kHz

32 kHz

Line Band

Voice

Compression

Audio Band

Sampling

Voice Packet 

Loss

Recovery

Delay

Time

(sec)

Band
Used

(kbps)

       Silence

0.02

776

 Redundancy

0.93

820

       Silence

0.02

392

 Redundancy

0.93

245

       Silence

1.3

68

 Redundancy

7.4

102

       Silence

2.6

34

 Redundancy

15

51

Rear

210

42.5

46

Front

188
180

Side

Rear

210

42.5

46

Front

188
180

Side

NX-100S

NX-100

Sub-Band

ADPCM

Sub-Band

ADPCM

Sub-Band

ADPCM

Sub-Band

ADPCM

Sub-Band

ADPCM

Sub-Band

ADPCM

Summary of Contents for NX-100

Page 1: ...on of high quality audio via IP networks Uses dedicated lines and internet for transmission to remote areas Reduces communications cost by allowing the internet to be used NX 100S Standard Model NX 100 Multi Function Model ...

Page 2: ...NX 100 NX 100S unit can simultaneously transmit audio signals to a maximum of 4 locations in the Unicast mode and to up to 64 locations in the Multicast mode This makes it possible to effectively perform company wide broadcasting and also to integrate broadcast diffusion functions Every NX 100 NX 100S is equipped with independent audio input and output connectors that can be operating simultaneous...

Page 3: ...uch as roadside locations railway stations and the like Automated announcements at unattended stations example example Digital Announcer CD player BGM and prerecorded voice announcements Announcer Headquarters Setting operation software supplied with the NX 100 Base Branch office Speaker ASDL or ISDN PC Remote Multi Point Access Broadcast System LAN Amplifier Speaker Amplifier Internet Router Mode...

Page 4: ... AD 246 Note When you need the AC adapter be sure to consult your TOA dealer Model No Power Source Current Consumption Audio Input Audio Output Frequency Response Distortion Control Input Control Output Network I F Network Protocol Audio packet Transmission System OperatingTemperature Operating Humidity Finish Dimensions Weight Accessory Option SPECIFICATIONS 0dB 1V APPEARANCE AND DIMENSIONAL DIAG...

Reviews: