background image

Removable terminal plug (2P)

(accessory)

Line connection terminals

N-8033MS rear

2 1

1 2

E-7000TB

Terminal board

Mini-clamp connector *

(Supplied with the 

N-8000EX/8010EX)

Twisted pair cable

N-8000EX/8010EX Exchange

16 lines

Both upper and lower 

terminals (clip terminals) 

are internally connected. 

3. WirinG

3.1. Connection to the exchange

To connect the cables from the N-8000EX/8010EX 

Exchange to the N-8033MS, use the removable terminal 

plug (2P) supplied with the N-8033MS.

The cables have no polarity.

* There are two types of Mini-clamp connectors, either of 

which is supplied with the N-8000EX/N-8010EX.

For details, refer to the next page.

3.4. the type of Cables

The types of cables are to be determined according to the 

following conditions.

•  Twisted pair wires (such as those used for electronic 

push-button telephone) are to be used for wiring 

between the Exchange and the stations in principle.

•  The number of cables pairs laid should be determined 

considering the possibility of future expansion of the 

system.

•  Outdoor wires should be used where wiring passes 

through inaccessible areas such as ceilings or under 

floors where the maintenance is not performed. Indoor 

wires may also be used, however, in case where there is 

no risk of deterioration due to exposure to heat, etc.

note

Specifications related to each junction are as follows.

Mini-clamp connector (N-8000EX/8010EX line terminal)

Conductor diameter:  ø 0.4 – 0.65 mm (AWG22 – 26), 

Solid wire

Outside diameter:  ø 1.05 mm or below

Clip terminal (E-7000TB)

Conductor diameter:  ø 0.4 – 0.8 mm (AWG20 – 26), 

Solid wire

Outside diameter:  ø 1.5 mm or below

Removable terminal plug (N-8033MS line terminal)

Conductor diameter:  ø 0.4 – 1.6 mm (AWG14 – 26), 

Solid wire/Stranded wire

External dial input terminal (N-8033MS)

Conductor diameter:  ø 0.8 – 1.3 mm (AWG16 – 20), 

Solid wire/Stranded wire

Conductor

Loop 

Maximum cable length 

diameter resistance between the Exchange and station.

(mm)

(Ω/ km) (Assuming that the loop resistance is 170 Ω.)

ø0.4

295

570 m

ø0.5

187

900 m

ø0.65

113

1.5 km

ø0.9

58

2.9 km

3.2. relations Between Core Diameter of Cable 

and Maximum Cable length

Refer to the following chart as guidelines when designing 

the distance between the Exchange and stations so that 

loop resistance value becomes 170 Ω or less.

3.3. Connection to external switch

External switches such as footswitches can be connected 

to the N-8033MS's external dial input terminals.

Terning on each switch connected to the terminal [7], [8], 

[9], or [C] permits the same operation as performed by 

pressing the dial [7], [8], [9], or [C].

An electrical current of 1 mA flows through each contact. 
note

The cable length from the external switch should not 

exceed 3 m.

COM

C

9

8

7

N-8033MS rear

7

8

9

C

COM

External dial input terminals

[Connections]

Press down.

Cable

External dial input 

terminal block

8 mm

Reviews: