1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe 

operation.

•  Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or 

cautions regarding safety.

•  After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property 

damage which could result from mishandling. Before operating your product, read this manual first and 

understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

WARNING

When Installing the Unit

• Do not expose the unit to rain or an environment 

where it may be splashed by water or other liquids, 

as doing so may result in fire or electric shock. 

•  Use  the  unit  only  with  the  voltage  specified  on 

the unit. Using a voltage higher than that which is 

specified may result in fire or electric shock.

• Do not cut, kink, otherwise damage nor modify 

the power supply cord. In addition, avoid using the 

power cord in close proximity to heaters, and never 

place heavy objects -- including the unit itself -- on 

the  power  cord,  as  doing  so  may  result  in  fire  or 

electric shock. 

• Avoid installing or mounting the unit in unstable 

locations, such as on a rickety table or a slanted 

surface. Doing so may result in the unit falling 

down and causing personal injury and/or property 

damage. 

•  Install the unit only in a location that can structurally 

support the weight of the unit and the mounting 

bracket. Doing otherwise may result in the unit 

falling down and causing personal injury and/or 

property damage.

When the Unit is in Use

• Should the following irregularity be found during 

use, immediately disconnect the power supply plug 

from the AC outlet and contact your nearest TOA 

dealer. Make no further attempt to operate the unit 

in this condition as this may cause fire or electric 

shock.

· If you detect smoke or a strange smell coming 

from the unit

·  If water or any metallic object gets into the unit 

· If the power supply cord is damaged (exposure of 

the core, disconnection, etc.)

·  If it is malfunctioning (no tone sounds.)

•  To prevent a fire or electric shock, never open nor 

remove the unit case as there are high voltage 

components inside the unit. Refer all servicing to 

your nearest TOA dealer.

•  Do not insert nor drop metallic objects or flammable 

materials in the ventilation slots of the unit's cover, 

as this may result in fire or electric shock.

•  Do not touch a plug during thunder and lightning, as 

this may result in electric shock. 

CAUTION

When Installing the Unit

• Never plug in nor remove the power supply plug 

with wet hands, as doing so may cause electric 

shock.

•  When unplugging the power supply cord, be sure to 

grasp the power supply plug; never pull on the cord 

itself. Operating the unit with a damaged power 

supply cord may cause a fire or electric shock.

•  Do not block the fan exhaust vent on the unit's rear. 

Doing so may cause heat to build up inside the unit 

and result in fire.

Indicates a potentially hazardous situation which, if mishandled, could 

result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage.

WARNING
CAUTION

Summary of Contents for N-8000EX

Page 1: ...TION MANUAL IP INTERCOM EXCHANGES N 8000EX N 8010EX Thank you for purchasing TOA s IP Intercom Exchanges Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment ...

Page 2: ...Caution when installing the unit 11 7 1 3 Mounting on the rack 11 7 2 Desk Top Installation 12 7 3 Wall Mounting 12 8 WIRING 14 8 1 Connection Diagram 14 8 2 Type of Cable 16 8 3 Relations Between Core Diameter of Cable and Maximum Cable Length 16 8 4 Connector Connection 17 8 4 1 Mini clamp connector connection 17 8 4 2 Removable terminal plug connection 18 8 5 E 7000TB Terminal Board Wiring 19 9...

Page 3: ...t and the mounting bracket Doing otherwise may result in the unit falling down and causing personal injury and or property damage When the Unit is in Use Should the following irregularity be found during use immediately disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer Make no further attempt to operate the unit in this condition as this may cause fire or elec...

Page 4: ...appareil Ne pas exposer l appareil à la pluie et le protéger de tout contact avec de l eau ou d autres liquides afin d éviter un incendie ou une électrocution Utilisez l appareil uniquement avec la tension spécifiée sur le chargeur L utilisation d une tension supérieure à celle spécifiée peut être à l origine d un incendie ou d une électrocution Ne pas couper entortiller modifier ou endommager le ...

Page 5: ...ent le cordon Utiliser l appareil avec un cordon d alimentation endommagé peut présenter un risque d incendie ou d électrocution Ne pas obstruer les fentes de ventilation sur le capot de l unité sous peine de provoquer une accumulation de chaleur à l intérieur de l appareil pouvant aboutir à un incendie Respecter les instructions ci dessous pour monter l appareil en bâti Risque d incendie ou de bl...

Page 6: ...dio interference in which case the user may be required to take adequate measures DESCRIPTION GÉNÉRALE Les unités N 8000EX et N 8010EX de TOA sont les centraux utilisés pour le système de paquet intercom des séries N 8000 intercom compatible avec un réseau IP utilisant une technologie de paquet audio 1 La connexion de centraux intercom IP qui permettent la connexion de 16 stations maximum par cent...

Page 7: ...of internal call 2 pairs of external call without PA paging output CARACTÉRISTIQUES Les centraux peuvent être distribués sur un réseau de communication de données Peut être connecté à un réseau local LAN ou étendu WAN existant Le système peut aussi facilement être connecté à un réseau fibre optique ce qui évite toute restriction sur la distance des stations Logiciel dédié permettant un contrôle ce...

Page 8: ...Maximum 80 Line Capacity Maximum 1 280 80 Exchanges x 16 stations per Exchange Speech Link Capacity N 8000EX Internal 4 links External Speech Link maximum 8 links Multicast paging Link maximum 4 links Unicast paging 1 link simultaneous access capacity N 8010EX Internal 1 link External Speech Link maximum 2 links Multicast paging Link maximum 2 links Unicast paging 1 link simultaneous access capaci...

Page 9: ...d this terminal Note This terminal is not a safety ground 7 Cooling fan CAUTION Do not block the fan exhaust vent Doing so may cause heat to build up inside the unit and result in fire 8 AC inlet Connects the supplied power cord Note If there is a danger of lightning strikes insert an appropriate surge arrester into the power line 9 Cord clamp Pass the power cord through this clamp to ensure that ...

Page 10: ...ante Par conséquent veiller à installer l équipement dans un environnement compatible à la température ambiante maximum spécifiée par le fabricant B Débit d air réduit L installation de l équipement en bâti ne doit pas compromettre le débit d air nécessaire à une utilisation sûre de l équipement C Charge mécanique Le montage de l équipement en bâti ne doit pas entraîner de danger dû à une surcharg...

Page 11: ...age en bâti sur le central Étape 2 Montez le central en bâti Do not stack up 3 Exchanges or more If 2 or more Exchanges are mounted in the Equipment rack be sure to mount the perforated panel of 1 U size PF 013B or more above and below every 2 Exchanges Using the supplied rack mounting screws install the terminal board in a location that facilitates wiring and maintenance work taking into consider...

Page 12: ...lied wall mounting bracket to the Exchange using each 2 supplied screws and removed screws from the case Étape 1 Installez la patte de montage mural fournie sur le central à l aide des 2 vis fournies et des vis démontées du boîtier N 8000EX 8010EX Plastic foot accessory Machine screw M4 x 20 accessory Vis de mécanique M4 x 20 accessoire Pied en plastique accessoire Tapping screw 3 x 8 accessory N ...

Page 13: ...l équipement et la fiche doit être facilement accessible Wood screw 3 5 x 20 accessory Wall surface Note Remarque Surface murale Vis à bois 3 5 x 20 accessoire Cord clamp Power supply cord Protect against disconnection Power supply plug Collier du cordon Cordon d alimentation Unlock cord clamp and run the power supply cord through it Keep the cable length between a power supply plug and cord clamp...

Page 14: ...fault occurs on the cable power cannot be supplied to the station even when the short or ground fault is removed To restore the situation be sure to disconnect the cable connector at the station or exchange and then connect it again after several seconds Both upper and lower terminals clip terminals are internally connected E 7000TB Terminal board Station Mini clamp connector 232D 02S1B DA5 DDK ac...

Page 15: ...cification of paging audio output 0 dB 600 Ω balanced 4 Paging contact output terminal connection N 8000EX only Paging contact output terminals have no polarity Refer to p 18 Removable terminal plug connection Specification of paging contact output No voltage make contact output Withstand voltage Max 24 V DC Control current Max 0 5 A 5 Network connection Can be connected to a network of 10BASE T 1...

Page 16: ...terioration due to exposure to heat etc Note Specifications related to each junction are as follows Mini clamp connector N 8000EX 8010EX line terminal Conductor diameter ø 0 4 0 65 mm AWG22 26 Solid wire Outside diameter ø 1 05 mm or below Clip terminal E 7000TB Conductor diameter ø 0 4 0 8 mm AWG20 26 Solid wire Outside diameter ø 1 5 mm or below Removable terminal plug N 8000EX Paging output Con...

Page 17: ... in equal length and insert them securely to a cover section transparent side of the mini clamp connector Note Insert the cable without stripping the cable jacket For cables refer to p 16 Type of Cable Step 2 With a pair of pliers lightly pinch the mini clamp cover and after ensuring that the cable is securely inserted firmly squeeze on the cover Note Squeeze on the mini clamp cover until it is co...

Page 18: ...t does not pull free If the cable pulls free loosen the terminal screw again and reconnect from Step 2 Use the screwdriver appropriate to the screws tightened into the terminal plug Step 4 Insert the wired terminal plug into the terminal block of the N 8000EX For cables refer to p 16 Type of Cable Note Do not solder plate on exposed inner cables when using a stranded wire 7 mm Removable terminal p...

Page 19: ...d press the YC 105 Dedicated Tool down onto the terminal from above Pressing down the YC 105 tool cuts off the excess cable end securing the connection For cables refer to p 16 Type of Cable Terminal board E 7000TB Cut end Cable Hook the cable onto the terminal without stripping the cladding Terminal Yellow Gray Clipping tool YC 105 Optional Bind the cables using cable clips supplied with the E700...

Page 20: ...wing command Drive where CD is placed index html For example when placing the CD in the d drive d index html Download our TOA Products Data web site https www toa products com international to get the up to date version for N 8000 software firmware and Instruction manuals The software version number can be confirmed using the Help menu The current firmware version can be confirmed on the system ma...

Reviews: