Toa N-8000AF Installation Manual Download Page 7

7

4. NOMENCLATURE AND FUNCTIONS

[Front]

1 2 3 4 5 6 7

8

9

10

11

12

13

14

15

16 17

1. Reset key [RESET]

Pressing this key reactivates this unit.

2. LNK/ACT indicator [LNK/ACT] (Green)

Lights when connected to a network, and flashes 

while transmitting or receiving data. 

3. Status indicator [STATUS] (Red)

Continuously  lights  while  data  is  written  to  an 

internal storage medium (FlashMemory).

Flashes if there is a failure.

4. Power indicator [POWER] (Green)

Lights when power is supplied to the unit.

5. MAC address

This is the address*

1

 used by the unit. Since the 

relationship of each exchange location to its MAC 

address  is  established  when  setting  the  network 

attributes,  keep  track  of  this  relationship  for  later 

use. 

*

1

  The inherent address assigned to each network 

component,  expressed  in  12-digit  hexadecimal 

notation. 

6. Signal indicator [SIGNAL] (Green)

Lights when audio is input. 

7. Peak indicator [PEAK] (Red)

Lights when over-input is applied to the audio input. 

8. Cord clamp

Pass the power cord through this clamp to ensure 

that  the  plug  does  not  pull  out  when  the  unit  is 

mounted to a wall. (Refer to p. 11.)

9. AC inlet

Connect the supplied power cord.

Note

If there is a danger of lightning strikes, insert an 

appropriate surge arrester into the power line.

 10. Audio output terminal [AUDIO OUTPUT]

This terminal connects to a recording device, etc.

(Refer to p. 14.

Max. 0 dB*

2

, 600 Ω or less, balanced

 11. Contact input terminals [CNT IN]

No-voltage make contact inputs.

Short-circuit  current:  under  5  mA,  Open-circuit 

voltage: 24 V 

Connect using a removable terminal plug. 

(Refer to p. 14.

 12. Contact output terminals [CNT OUT]

Relay contact outputs.

Withstand voltage: 24 V DC, Control current: 2 – 

500 mA 

Connect using a removable terminal plug. 

(Refer to p. 14.

 13. Network connection terminal [10/100M]

Connects  to  a  10BASE-T-  or  100BASE-TX-

compatible network. (Ethernet RJ-45 jack)

 14. Functional earth terminal [SIGNAL GND]

Ground this terminal.

Note: This terminal is not for protective earth.

 15. Input volume control [INPUT VOLUME]

Adjusts  the  input  signal  level.  Use  this  volume 

control to adjust the signal level to below the point 

where the Peak Signal Indicator begins to light. 

 16. Audio input terminal [AUDIO INPUT]

Connect the microphone or other sound source 

equipment to this terminal.   

(Refer to p. 14.

Max. 0 dB*

2

, 2 kΩ or more, balanced 

 17. Time sync input terminal [TIME SYNC]

Connect the Program Timer, etc. to this terminal. 

Use the removable terminal plug for connection 

of this terminal. 

(Refer to p. 14.

*

2

 0 dB = 1 V

[Rear]

Summary of Contents for N-8000AF

Page 1: ...TALLATION MANUAL AUDIO INTERFACE UNIT N 8000AF Thank you for purchasing TOA s Audio Interface Unit Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment ...

Page 2: ...NS 7 Front 7 Rear 7 5 INSTALLATION 8 5 1 Equipment Rack Mounting 8 5 1 1 Setting space 8 5 1 2 Mounting on the rack 9 5 2 Desk Top Installation 10 5 3 Wall Mounting 10 6 WIRING 12 6 1 Connection Diagram 12 6 2 Type of Cable 14 6 3 Removable terminal plug connection 14 7 ACCESSORIES 15 8 OPTIONAL PRODUCTS 15 ...

Page 3: ...lling down and causing personal injury and or property damage When the Unit is in Use Should the following irregularity be found during use immediately disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the un...

Page 4: ...es moyennement graves ou mineures et ou des dommages matériels AVERTISSEMENT ATTENTION AVERTISSEMENT Lors de l installation de l appareil Ne pas exposer l appareil à la pluie et le protéger de tout contact avec de l eau ou d autres liquides afin d éviter un incendie ou une électrocution Utilisez l appareil uniquement avec la tension spécifiée sur le chargeur L utilisation d une tension supérieure ...

Page 5: ...brancher le cordon d alimentation veiller à le tenir par sa fiche ne jamais tirer directement le cordon Utiliser l appareil avec un cordon d alimentation endommagé peut présenter un risque d incendie ou d électrocution Respecter les instructions ci dessous pour monter l appareil en bâti Risque d incendie ou de blessure corporelle Installer le bâti sur un sol stable Le fixer à l aide de boulons d a...

Page 6: ... GENERAL DESCRIPTION TOA s N 8000AF is Audio interface unit used for the N 8000 Series Packet Intercom System IP network compatible intercom employing packet audio technology It has an analog audio input and output a time synchronization contact input and each 8 contact inputs and outputs Connecting the unit to the LAN permits recording of conversations chime broadcast at regular intervals time si...

Page 7: ...e If there is a danger of lightning strikes insert an appropriate surge arrester into the power line 10 Audio output terminal AUDIO OUTPUT This terminal connects to a recording device etc Refer to p 14 Max 0 dB 2 600 Ω or less balanced 11 Contact input terminals CNT IN No voltage make contact inputs Short circuit current under 5 mA Open circuit voltage 24 V Connect using a removable terminal plug ...

Page 8: ... A Température ambiante élevée si l appareil est installé dans un bâti fermé ou en même temps que d autres appareils la température à l intérieur risque de devenir supérieure à la température ambiante Par conséquent veiller à installer l équipement dans un environnement compatible à la température ambiante maximum spécifiée par le fabricant B Débit d air réduit L installation de l équipement en bâ...

Page 9: ... taraud 3 x 14 1 Vis taraud 3 x 8 1 Patte vierge 1 Vis taraud 3 x 8 1 Patte de montage 1 Rondelle en fibre pour M5 1 Vis de montage en bâti 5 x 12 1 Tapping screw 3 x 14 2 Rack mounting bracket 2 Rack mounting screw 5 x 12 2 Fiber washer for M5 2 Tapping screw 3 x 14 2 Coupler 2 Machine screw 3 x 12 2 N 8000AF N 8000AF Vis taraud 3 x 14 2 Rondelle en fibre pour M5 2 Vis de montage en bâti 5 x 12 2...

Page 10: ...all using an optional YC 850 Wall mounting bracket L unité N 8000AF peut être montée au mur à l aide d une patte de montage mural YC 850 Step 1 Install the YC 850 to the N 8000AF Étape 1 Installez l unité YC 850 sur l unité N 8000AF Wall mounting bracket YC 850 Machine screw M3 x 6 supplied with the YC 850 Pattes de montage mural YC 850 Vis de mécanique M3 x 6 fournie avec l unité YC 850 N 8000AF ...

Page 11: ...che dispositif de déconnexion doit être facilement accessible Cord clamp Power supply cord Protect against disconnection Power supply plug Unlock cord clamp and run the power supply cord through it Note Keep the cable length between a power supply plug and cord clamp as short as possible Protection contre les ruptures d alimentation prise d alimentation Déverrouillez le collier à cordon et glissez...

Page 12: ... supply system 1 Note If there is a danger of lightning strikes insert an appropriate surge arrester into the power line To mixer power amplifier etc To microphone audio device etc To network RJ 45 connector N 8000AF Connected Unit Hot H Cold C Earth E Make connections as follows when the connected device has unbalanced inputs N 8000AF Audio interface unit Contact input signals Contact input signa...

Page 13: ...e sync input terminal connections Connect the program timer etc to this terminal Refer to p 14 Removable terminal plug connection Specification of no voltage make contact input Short circuit current 5 mA Open circuit voltage 24 V 5 Contact input terminal connection Refer to p 14 Removable terminal plug connection Specification of no voltage make contact input Short circuit current 5 mA Open circui...

Page 14: ...UTP category 5 Straight through cables with RJ45 connector are to be used for connecting to IP network The number of cables pairs laid should be determined considering the possibility of future expansion of the system Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under floors where the maintenance is not performed Indoor wires may also be used howe...

Page 15: ...er to execute the following files or use Start Run in the Task Bar and enter the following command Drive where CD is placed index html For example when placing the CD in the d drive d index html 8 OPTIONAL PRODUCTS AC power cord 2 m 1 CD for PC setting maintenance use 1 Removable terminal plug 2 pins 1 Removable terminal plug 3 pins 2 Removable terminal plug 5 pins 2 Removable terminal plug 8 pins...

Page 16: ... for N 8000 software firmware and Instruction manuals The software version number can be confirmed using the Help menu The current firmware version can be confirmed on the system management screen displayed when the browser establishes the connection to the Exchange The instruction manual version number can be confirmed by checking the preparation date month and year shown at the lower right corne...

Reviews: