1. IMPORTANT SAFETY INSTRUCTIONS

• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

• Do not defeat the safety purpose of the polarized or grounding-type plug. A grounding type plug has two

   blades and a third grounding prong. If the provided plug does not fit into your outlet, consult an electrician

   for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

• Only use attachments/accessories specified by the manufacturer.
• Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,

or  sold  with  the  apparatus.  When  a  cart  is  used,  use  caution  when  moving  the

cart/apparatus combination to avoid injury from tip-over.

• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the  apparatus  has  been

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have

fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or

has been dropped.

INSTRUCTIONS ESSENTIELLES POUR LA SÉCURITÉ

• Lire ces instructions.
• Conserver ces instructions pour référence ultérieure.
• Respecter tous les avertissements.
• Suivre toutes les instructions.
• Ne pas utiliser cet appareil à proximité d'eau.
• Nettoyer uniquement à l'aide d'un chiffon sec.
• Ne pas obstruer les orifices de ventilation. Installer conformément aux instructions du fabricant.
• Ne pas installer à proximité de sources de chaleur telles que des radiateurs, des registres thermiques, des

chaudières ou d'autres appareils (notamment des amplificateurs) produisant de la chaleur.

• Ne pas contourner la fonction de sécurité de la fiche polarisée ou de mise à la terre. Une fiche de mise à 

   la terre est équipée dedeux broches et d'une troisième pour la mise à la terre.  Si  la  fiche  fournie  ne

   peut  être  insérée  dans  la  prise  électrique  souhaitée,  consulter  un électricien pour faire remplacer cette

   dernière.

• Protéger le cordon d'alimentation pour éviter qu'il ne soit piétiné ou pincé, notamment au niveau des fiches,

des prises de courant ou de son point de sortie de l'appareil.

• Utiliser uniquement les accessoires spécifiés par le fabricant.
• Utiliser uniquement avec le chariot, support, trépied, la patte de montage ou la table

spécifiés par le fabricant ou vendus avec l'appareil.  En cas d'utilisation  d'un  chariot,
manipuler  la  combinaison  chariot/appareil  pour  éviter  les  blessures  dues  à  un

renversement.

• Débrancher cet appareil pendant les orages ainsi que lorsqu'il reste inutilisé pendant une période prolongée.
• La maintenance de l'appareil doit être confiée à un technicien après-vente qualifié. Une maintenance s'avère

nécessaire si l'appareil est endommagé (au niveau du cordon d'alimentation ou de la fiche), a été mouillé

par un liquide, un objet est tombé à l'intérieur, s'il a été exposé à la pluie ou l'humidité, s'il ne fonctionne pas

normalement ou s'il est tombé.

2

Summary of Contents for M-124FX-EB

Page 1: ...e use of your equipment 1 IMPORTANT SAFETY INSTRUCTIONS 2 2 SAFETY PRECAUTIONS 3 3 GENERAL DESCRIPTION 5 5 4 FEATURES 5 5 NOMENCLATURE AND FUNCTIONS 6 POWER AND LEVEL ADJUSTMENT 7 CONNECTIONS 12 11 CO...

Page 2: ...ces instructions Conserver ces instructions pour r f rence ult rieure Respecter tous les avertissements Suivre toutes les instructions Ne pas utiliser cet appareil proximit d eau Nettoyer uniquement l...

Page 3: ...nto the unit If the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric s...

Page 4: ...it as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume...

Page 5: ...up 3 4 and Main L R bus assign for each channel 5 NOMENCLATURES AND FUNCTIONS With USB port record from MAIN MIX OUT and play to CH9 10 Built in 24 bit DSP effect with 100 presets Built in USB player...

Page 6: ...you turn this control up you will boost all the frequencies above 12 kHz shelving filter You will add transparency to vocals and guitar and also make cymbals crispier Turn the control down to cut all...

Page 7: ...is fader will adjust the overall level of this channel and set the amount of signal sent to the main output 19 GR1 2 GR 3 4 L R Each channel provides three push buttons GR1 2 GR3 4 L R The three butto...

Page 8: ...X4 it can also provide the necessary level adjustment for the internal effect signal 28 DFX OUT These control is used to determine the internal DSP module levels and DFX sends output which can be vari...

Page 9: ...to the next track and start playing 41 REPEAT Press this key the player will change between the following four modes PER ALL means to repeat all tracks in the memory mark on the screen is PEP1 means...

Page 10: ...rnal footswitch for your convenient operation it has the same function as DFX MUTE button 49 CONTROL ROOM These TRS phone jacks will be used to send the signal to studio monitor speakers or to a secon...

Page 11: ...nd you should turn down your volume now don t let the PEAK lights on long time it means over load may damage the system POWER ON Peripheral devices Source Mixer Power Amplifier POWER OFF 40 18 15 12 9...

Page 12: ...t 2 Hot 1 Earth seen from soldering side MAIN MIX OUTPUT connection 3 Pin XLR line socket Use for balanced outputs Two core shielded cable One core shielded cable To be used when the processor does no...

Page 13: ...Interface Drum Machine CD Player 1 DAT Recorder Headphone 8 EXAMPLE OF EXTERNAL EQUIPMENT CONNECTIONS Wireless Microphone Power Amplifier Stage Monitors Active speaker Keyboaro MIC 1 MIC 2 MIC 3 Drum...

Page 14: ...mulate classic bright vocal plate Guitar Effect Chorus Guitar Effect Rotary Guitar Effect Tremolo Rev delay time 0 8 0 9s pre delay 10 45ms Decay time 0 7 2 1s Pre delay 20 45ms Decay time 3 6 5 4s Pr...

Page 15: ...11 BLOCK DIAGRAM 15 4 FOOT SW DFX OUT GR1 2 OUT GR3 4 OUT DFX OUT MIC 1 4 IN LINE 1 4 IN MIC 5 8 IN LINE 5 8 IN LINE 5 8 IN LINE 9 10 IN LINE 9 10 IN LINE 11 12 IN LINE 11 12 IN PC IN OUT...

Page 16: ...tor Audio Output MAIN INSERT 0 dBu 120 stereo pair unbalanced TRS phone jack Power Consumption 30W PC input 30 dBu USB B connector USB input Audio formats MP3 Format FAT16 FAT32 Max 32GB USB A connect...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ation for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany URL http...