Toa IP-300D Operating Instructions Manual Download Page 6

Power Input terminal

Electrically-balanced input terminals. The XLR
connector is connected in parallel with a balanced
phone jack.

• XLR connector

Pin No.1: GROUND

No.2: HOT
No.3: COLD

• Balanced phone jack

T (Tip): HOT   R (Ring): COLD   S(Sleeve): GROUND

Output mode selector switch

Selects STEREO, BTL or PARALLEL mode.

• STEREO mode

Channels 1 and 2 are operated independently. (The
unit functions as a normal stereo amplifier.) Channel
1 input signal goes to Channel 1 output, and
Channel 2 input signal goes to Channel 2 output. 

• BTL mode

The unit functions as a monaural amplifier with 1
input and 1 output. Channel 1 input signal goes to
both output BTL (+) and (–) terminals.

• PARALLEL mode

The unit functions as a monaural amplifier with 1
input and 2 outputs. Channel 1 input signal goes to
the outputs of both Channels 1 and 2. Input signal
levels of channels 1 and 2 can be set independently.

[Precautions]

Use only Channel 1 input terminal when in BTL or
PARALLEL mode. Do not use Channel 2 input terminal.

Confirm the position of the output mode selector switch
before switching on the power. Be sure to switch off the
power when changing mode switch settings.

Level control switch

Usually, set this switch to OFF. When an interface unit
is connected, shifting this switch to ON permits external
input level adjustment.

[Precautions]

No sound is output if the level control switch is set to
ON without connecting an interface unit. Confirm the
switch position before switching on the power. Be sure
to switch off the power when changing control switch
settings. 

Control I/O terminal

Connects to an interface unit when monitoring or
performing remote controls from external equipment.
For details, contact your TOA dealer. 

[Precautions]

No other unit other than an interface unit must be
connected to the terminal. Be sure to switch off the
power when connecting an interface unit.

Output terminal (with a protection cover)

Connect speaker cables to these terminals. Because
the upper terminals are connected in parallel with the
lower terminals, both terminals can be used
simultaneously. Refer to p.8 for speaker cable
connections.

[Precautions]

Be sure to switch off the power when connecting the
speaker cables. Never connect two amplifier outputs in
parallel under any circumstances.

Grounding terminal for signals

When the power amplifier is connected to other
equipment, grounding sometimes creates a loop,
producing hum noise. This loop can be cut and noise
reduced by removing a shorting metal piece connecting
two terminals.

AC inlet

Cord hanger

16

15

14

13

12

11

10

9

6

[ Rear panel ]

9

9

11

12

11

12

14

10

13

15

16

16

2

1

3

1

2

3

T
R
S

T R

S

Phone plug

Phone jack

Summary of Contents for IP-300D

Page 1: ...AUTIONS 2 2 GENERAL DESCRIPTION 4 3 FEATURES 4 4 HANDLING PRECAUTIONS 4 5 NOMENCLATURE AND FUNCTIONS Front panel 5 Rear panel 6 6 INSTALLATION 7 7 CONNECTIONS 8 8 CLEANING THE FILTER 9 9 REMOVING THE...

Page 2: ...he unit s terminal cover after connection completion Because the voltage of up to 100 V is applied to the output terminals never touch these terminals to avoid electric shock Avoid installing or mount...

Page 3: ...two or more persons Falling or dropping the unit may cause personal injury and or property damage When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break...

Page 4: ...emperature rise Large output screw terminals 10 mm in width allow connection of solderless terminals with diameter of 9 5 mm Because two of each of positive and negative terminals are provided even th...

Page 5: ...mp also lights red when a protection circuit is activated Refer to p 11 Table for protection circuit actions for details Level control bypass indicator lamp Lights yellow when the level control switch...

Page 6: ...connected shifting this switch to ON permits external input level adjustment Precautions No sound is output if the level control switch is set to ON without connecting an interface unit Confirm the sw...

Page 7: ...lish this keep the rear side of rack open no panel is mounted and mount a ventilation panel of over 1 unit size in the uppermost and lowermost rack positions on the rack front When installing in the r...

Page 8: ...for connections for each output mode Since the upper output terminals are connected in parallel with the lower terminals both terminals can be used simultaneously STEREO mode BTL mode PARALLEL mode P...

Page 9: ...lied screws M4 x 20 6 Attach the handle cover to the unit 1 Switch off the amplifier power 2 Pull the filter from the front panel as shown in the figure 3 Clean the filter 4 Fit the filter in place Pr...

Page 10: ...SIGNAL PEAK PROTECT VR BYPASS CONTROL I O HEAT SINK TEMPERATURE SENSOR VI LIMITER SHORT DETECTOR CH1 POWER AMP CIRCUIT POWER SIGNAL PEAK PROTECT VR BYPASS CONTROL I O ATT OFF ON ATT OFF ON VR CONTROL...

Page 11: ...Speaker loads cut by output relay Indicator Peak indicator lights Protection circuit indicator lights Protection circuit indicator lights Protection circuit indicator lights Remedy Remove overload Che...

Page 12: ...Power supply AC inlet POWER green SIGNAL x 2 green PEAK x 2 red PROTECT x 2 red VR BYPASS x 2 yellow 230 VAC 10 50 60 Hz 430 VA 660 VA 940 VA 1200 VA 1800 VA 2400 VA Panel Zinc diecasting black paint...

Reviews: